• Operation Revised 6/2013 www.stingerworld.com CS150 CAP STAPLER OWNER’S MANUAL ! • Maintenance • Safety • Warranty PLEASE READ! This manual contains important information about product safety.
www.stingerworld.com WELCOME TO STINGER Congratulations on purchasing the STINGER CS150 Cap Stapler. You have selected a brand and a tool that you can count on to deliver best practice installation, and perform job after job. Please take the time to read and understand the information contained in this Owner’s Manual before operating or maintaining the STINGER CS150 Cap Stapler. The CS150 is intended for securing housewrap, foamboard and roofing felt only.
www.stingerworld.
www.stingerworld.com IMPORTANT INFORMATION ! PERSONAL SAFETY ITEMS • Do not use tool prior to reading the Owner’s Manual. • Always wear eye protection that conforms to ANSI requirements (Z87.1) and provides protection against flying particles both from the front and side. Eye protection should be worn by the operator and by others in the work area. Eye protection is required to protect against flying fasteners and debris that could possibly cause severe eye injury.
www.stingerworld.com IMPORTANT INFORMATION AIR SUPPLY AND CONNECTIONS • Use only clean, regulated compressed air as a power source for this tool. Do not use bottle gases, combustible gases or oxygen as a power source for the tool as the tool may explode. • Do not use air supply pressures that exceed 105 PSI. Exceeding the recommended maximum operating air pressure will greatly increase tool wear. • The air supply must be capable of maintaining the operating air pressure of the tool.
www.stingerworld.com IMPORTANT INFORMATION OPERATION OF THE TOOL • Never inspect, maintain, repair, adjust, clear a jam or store the tool with the air connected. • Never use the tool in proximity of flammable gases or liquids, as some tools will create sparks that can be an ignition source for a fire or explosion. • Always inspect the safety device for damage and proper operation prior to operation. • Never assume the tool is empty of fasteners.
www.stingerworld.com TOOL SPECIFICATIONS Operating pressure 95-105 psi Weight 4.2lbs Staple capacity 200 staples (2-100 count strips) Cap capacity 200 plastic collated caps (1 reel) Air inlet 3/8 NPT Fasteners STINGER StaplePac® only. Each 2000 count StaplePac consists of 20 strips of 7/8”, 1-1/4” and 1-1/2” 18 gauge staples (100 staples per strip) and 10 reels of 1” diameter plastic collated caps (200 caps per reel). 10. 1. Magazine 2. Magazine Cover 14. 3. Cover Release Tab 4.
www.stingerworld.com LOADING THE TOOL FOR USE WITH 7/8”, 1-1/4”, or 1-1/2” STINGER STAPLEPAC® CAP STAPLES ONLY • Disconnect air. Open the Magazine Cover by pushing the green Cover Release Tab and lifting. • Place cap reel in Magazine. Make sure the front end of the cap coil is placed over the cap guide area of the Magazine. Insert lead cap into the Feed Chute. • Slide caps along the Feed Chute with fingers until they engage the Cap Feeder.
www.stingerworld.com OPERATING THE TOOL 1. Do not use tool prior to reading the STINGER CS150 Owner’s Manual. 2. Read warning label(s) on the tool. 3. Visually inspect the tool for worn or damaged parts. 4. Wear appropriate eye and ear protection. 5. Install a male pneumatic fitting into the End Cap of the tool, ensuring that the fitting allows the tool to exhaust any air in the tool when the air hose is disconnected. 6. Add 2 drops of non-detergent, 20-weight oil into the male fitting daily.
www.stingerworld.com OPERATING THE TOOL 11. Cycle the tool on a scrap work piece to evaluate the depth of penetration by the fastener into the work piece. 12. To adjust the depth of penetration, regulate the air pressure at the regulator and/or disconnect the air hose, adjust the depth control screw, connect the air hose, and cycle the tool on a scrap work piece to evaluate the adjustment. 13.
www.stingerworld.
www.stingerworld.com STINGER CS150 PARTS LIST Ref.
www.stingerworld.com MAINTANANCE & STORAGE MAINTENANCE 1. Disconnect the air hose from the tool when performing inspections, maintenance or repairs. 2. Use air line lubricators. If lubricators are not available, or if hose length exceeds 10 feet, add 2 drops of non-detergent 20-weight oil daily into the air inlet of the tool. 3. Whenever repairs or replacement of parts inside the body occur, check the piston “O” ring for adequate grease lubrication. 4.
www.stingerworld.com WARRANTY WARRANTY ITEMS 1. Warranty for cap assemblies, castings and housing castings is one year. 2. Warranty for bumpers, “O” rings, driver blades and piston rings is not applicable as they are normal wearing parts whose life is dependent on application. 3. Warranty for all other parts is 90 days. WARRANTY CONDITIONS 1. The beginning date in which the warranty is in force is the date of purchase. 2. The warranty is not transferable. 3.
www.stingerworld.com TROUBLESHOOTING Disconnect the air hose from the tool when performing inspections, maintenance or repairs. PROBLEM: CORRECTION: 1. Tool operates, but no fasteners are driven. • Check Magazine for proper fasteners. Fasteners should slide freely in and out of the magazine. 2. Cap leaks air. • Tighten cap screws. 3. Fasteners jam in nose of tool. • Remove fasteners from Magazine. • Open Quick-Clear™ Lever (if applicable), remove jammed fastener and close Latch. • Load tool. 4.
Visit our website at www.nationalnail.com to learn more about our products and services. 2964 Clydon SW, Grand Rapids MI 49519, USA Phone: 800-968-6245 Fax: 616-531-5970 www.stingerworld.com Contact Inside Sales at 800-746-5659 to place an order for replacement parts.