Use and Care Manual

www.nationalnail.com
OPERATING THE TOOL
7
1. Do not use tool prior to reading the Owner’s Manual.
2. Read warning label(s) on the tool.
3. Visually inspect the tool for worn or damaged parts.
4. Wear appropriate eye and ear protection.
5. Install a male pneumatic fitting into the end cap of the tool, ensuring that the fitting allows the
tool to exhaust any air in the tool when the air hose is disconnected.
6. Add 2 drops of non-detergent, 20-weight oil into the male fitting.
7. Connect the air hose using a quick connect fitting to the tool, and check the air pressure
reading on the regulator to ensure it does not exceed 105 PSI. Check the tool for any air
leaks.
8. Place the tool, empty of fasteners, in operating position on a scrap work piece. Fully depress
the safety and pull the trigger to verify that the tool cycles.
9. Disconnect the air hose from the tool when:
Loading staples and/or caps
Performing inspection, maintenance or repair
Clearing a staple or collated cap jam
The tool is not in use
Leaving the work area
Moving the tool to another work location
Handing the STINGER CS58 to another person
Storing the tool
10. Following recommended loading instructions, load the fasteners approved for use in the tool.