Datasheet

1/7
®
BTA/BTB12 and T12 Series
SNUBBERLESS™, LOGIC LEVEL & STANDARD 12A TRIACS
October 2001 - Ed: 4
MAIN FEATURES:
DESCRIPTION
Available either in through-hole or surface-mount
packages, the BTA/BTB12 and T12 triac series is
suitable for general purpose AC switching. They
can be used as an ON/OFF function in
applications such as static relays, heating
regulation, induction motor starting circuits... or for
phase control operation in light dimmers, motor
speed controllers,...
The snubberless versions (BTA/BTB...W and T12
series) are specially recommended for use on
inductive loads, thanks to their high commutation
performances. By using an internal ceramic pad,
the BTA series provides voltage insulated tab
(rated at 2500V RMS) complying with UL
standards (File ref.: E81734)
Symbol Value Unit
I
T(RMS)
12 A
V
DRM
/V
RRM
600 and 800 V
I
GT (Q
1
)
10 to 50 mA
ABSOLUTE MAXIMUM RATINGS
Symbol Parameter Value Unit
I
T(RMS)
RMS on-state current (full sine wave)
D
²
PAK/TO-220AB
Tc = 105°C
12 A
TO-220AB Ins. Tc = 90°C
I
TSM
Non repetitive surge peak on-state
current (full cycle, Tj initial = 25°C)
F = 50 Hz t = 20 ms 120 A
F = 60 Hz t = 16.7 ms 126
I
²
tI
²
t Value for fusing
tp = 10 ms 78
A
²
s
dI/dt
Critical rate of rise of on-state current
I
G
= 2 x I
GT
, tr 100 ns
F = 120 Hz Tj = 125°C 50 A/µs
V
DSM
/V
RSM
Non repetitive surge peak off-state
voltage
tp = 10 ms Tj = 25°C
V
DRM
/V
RRM
+ 100
V
I
GM
Peak gate current tp = 20 µs Tj = 125°C 4 A
P
G(AV)
Average gate power dissipation Tj = 125°C 1 W
T
stg
T
j
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
°C
G
A2
A1
G
A2
A2
A1
A2
A2
A1
G
D
2
PAK
(T12-G)
G
A2
A1
TO-220AB Insulated
(BTA12)
TO-220AB
(BTB12)