Datasheet
STE100P
22/31
Figure 9. Fast Link Pulse timing
Table 8. AC Specifications
Symbol Parameter Test Condition Min. Typ. Max. Units
100Base-TX Transmitter AC Timings Specification
Tjit TDP-TDN Differential Output
Peak Jitter
1.4 ps
MII Management Clock Timing Specifications
t1 MDC High Pulse Width 200 — ns
t2 MDC Low Pulse Width 200 — ns
t3 MDC Period 400 — ns
t4 MDIO(I) Setup to MDC Rising
Edge
10 — ns
t5 MDIO(I) Hold Time from MDC
Rising Edge
10 — ns
t6 MDIO(O) Valid from MDC Rising
Edge
0 300 ns
Tflpw
Tflbw
Tflbp
Tflcpp
Tflcpd