STE100P
24/31
Figure 11. MII Receive Timing
Figure 12. MII Transmit Timing
Table 8. AC Specifications
Symbol Parameter Test Condition Min. Typ. Max. Units
MII Transmit Timing Specification
t1 TX-ER,TX-EN,TXD[3:0] Setup to
TX-CLK Rise
10 — ns
t2 TX-ER,TX-EN,TXD[3:0] Hold
After TX-CLK Rise
025ns