Datasheet
Application examples and ideas L6563H
40/49 Doc ID 16047 Rev 3
Figure 56. L6563H 100 W TM PFC evaluation
board: compliance to EN61000-3-2
standard
Figure 57. L6563H 100 W TM PFC evaluation
board: compliance to JEITA-MITI
standard
Vin = 230 Vac - 50 Hz, Pout = 100 W
THD = 7.58%, PF = 0.979
Vin = 100 Vac - 50 Hz, Pout = 100 W
THD = 2.5%, PF = 0.997
Figure 58. L6563H 100 W TM PFC evaluation
board: input current waveform
@230-50 Hz - 100 W load
Figure 59. L6563H 100W TM PFC evaluation
board: input current waveform
@100 V-50 Hz - 100 W load
0.0001
0.001
0.01
0.1
1
1 3 5 7 9 111315171921232527293133353739
Harmonic Order [n]
Harmonic Curr ent [A]
Measured value EN61 000 -3- 2 cl as s -D l i m it s
0.0001
0.001
0. 01
0.1
1
10
1 3 5 7 9 11 13 15171921 2325272931 33353739
Harmonic Order [n]
Harmonic Current [A]
Measured value JEITA-MITI Class-D limits