1 Getting started
Connect the X-NUCLEO-NFC05A1 to an STM32 Nucleo-64 development board. The PC
USB port has to be capable of delivering at least 300 mA at 5 V supply. A demo software is
available for download at www.st.com to be programmed onto the STM32 Nucleo.
1.1 Hardware requirements
The X-NUCLEO-NFC05A1 expansion board is designed to be used with any STM32
Nucleo board, although complete testing has been performed using the NUCLEO-L476RG
hosting the STM32L476RG microcontroller.
The STM32 Nucleo firmware and the related documentation are available at
http://www.st.com/stm32nucleo.
1.2 System requirements
To use the STM32 Nucleo boards with the X-NUCLEO-NFC05A1 expansion board the
following software and hardware are required:
an STM32 Nucleo-64 development board
a Windows
®
PC to install the firmware package
a USB type A to Mini-B USB cable to connect the Nucleo board to the PC
unit must be supplied by a safety extra low voltage (SELV) limited power source
through the USB port, the source should not exceed 60Vdc / 8A / 100VA
To install the board firmware package (order code: X-CUBE-NFC5) the PC must have:
128 MB of RAM
40 MB of free hard disk space
The X-CUBE-NFC5 firmware and the related documentation are available at www.st.com.