Datasheet

Absolute maximum ratings and operating conditions TS431
2/14 DocID5558 Rev 10
1 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
KA
Cathode to anode voltage 10 V
I
k
Continuous cathode current range -20 to +40 mA
I
ref
Reference input current range -0.05 to +3 mA
P
d
Power dissipation
(1)
TO92 package
SOT23-5 package
1. T
junction
= 150 °C, T
amb
= 25 °C with
R
thJA
= 200 °C/W for TO92 package and
R
thJA
= 250 °C/W for SOT23-5L package
625
500
mW
T
stg
Storage temperature range -65 to +150 °C
Table 2. Operating conditions
Symbol Parameter Value Unit
V
KA
Cathode to anode voltage 1.24 to 6 V
I
k
Cathode current
(1)
1. Please refer to Section 3: Application information for more details.
0.06 to 30 mA
T
oper
Operating free air temperature range -40 to +125 °C