User's Manual

STONEX R2 PLUS
45
6. After finishing measurement:
Press F1: [
REC] to save;
Press F2: [
NEZ] to display NEZ coordinate;
Press F3: [
NO] back to step 6;
Press F4: [
YES] back to offset mode.
9.3 Dual-Distance Offset Measurement
By measuring the distance between the target point and the two offset points. Set two
offset points (1st target and 2nd target) on a straight line from the target point, measure
the 1st and 2nd target, then input the distance between the 2nd target and the target point
to find the target point.
Procedure of dual-distance offset measurement
1. Set two offset points (1
st
target, 2
nd
target) on a
straight line from the target point and use the offset
points as target.
2. Select [
MENU] at P2 in measure mode, and then
select “
4. Offset”, or press F3: [OFST] at P3 directly.
3. Select “
4. Offset/2Dist” after inputting the
instrument occupied data, see “ § 6.1 Input the
occupied point data”.
Target point
Instrument station
Offset point
(Target)
Offset point
(Target)
Menu P1
1.Coordinate
2.Stake out
3.Area
4.Offset
5.MLM
6.REM
7.Resection
Offset
1.Occ. Orientation
2.Offset/Dist
3.Offset/Angle
4.Offset/2Dist
Offset/Ang
SD 13.511m
VA 346.9636gon
HA 249.0298gon
REC NEZ M NOS YES