User's Manual

STONEX R2 PLUS
70
19.1 Two Point Arc Staking Out
1. Press F2: [MENU] on P2 of the basic measurement
mode, select 7.Arc Staking out to enter arc staking
out menu, select 1.Occ.Orientation to set the station.
And then select 2. 2pt+radius arc to start 2-point arc
staking out measurement.
2. Input the coordinate of arc start point.
Press F1[READ] to read the existed coordinate as
stake out coordinate
Press F4:[OK] to set the data.
3. Input the coordinate of arc end point.
Press F1[READ] to read the existed coordinate as
stake out coordinate
Press F4:[OK] to set the data.
4. Input the radius of arc, press F4:[OK] to set the
data.
5. Press F1:[MEAS] to measure current rod, the
staking date will display.
Station - the station on the arc computed radially
from the current position of the prism.
Offset – offset distance from the current position to
the arc.
S-O dHA – offset angle from the current position to
the arc
Fill/Cut – Cut value indicate that the rod is higher than the arc, fill indicates the it is
lower
In/Out– This is the distance you need to move in out to get to the arc.
Arc Stakeout
1.Occ.Orientation
2.2pt+radius arc
3.Three Point arc
Define/Start PT
Pt# J2
Np: 11.829
Ep: 0.000
Zp: 1.846
READ R E C MEAS OK
Define/End PT
Pt# J3
Np: 11.282
Ep: -2.130
Zp: 1.503
READ R E C MEAS OK
Arc define/Rad Input
Rad 100.000
OK
Are stake out/Measure
Stn : 2.930m
Offset: 8.304m
S-O dHA 12 27 49
Fill: 1.545
MEAS OK