User's Manual
STONEX R2 PLUS
72
4. Input the coordinate of arc middle point.
Press F1[READ] to read the existed coordinate as
stake out coordinate
Press F4:[OK] to set the data.
5. Press F1:[MEAS] to measure current rod, the
staking date will display.
Station - the station on the arc computed radially
from the current position of the prism.
Offset – offset distance from the current position to
the arc.
S-O dHA – offset angle from the current position to
the arc
Fill/Cut – Cut value indicate that the rod is higher
than the arc, fill indicates the it is lower
In/Out(from Rod to A)– This is the distance you
need to move in out to get to the arc.
6. According the S-O dHA angle to move the rod until
the telescope sight intersect the arc.
7. Repeat moving and measuring the rod until all the
stake data are accepted. Press F4: [ESC] to escape this
program.
Are stake out/Measure
Stn : 0.012m
Offset: 0.003m
In: 0.003m
Fill: 0.006m
MEAS OK
Are stake out/Measure
Stn : 0.015m
Offset: 10.025m
In: 0.013m
Fill: 0.306m
MEAS OK
Are stake out/Measure
Stn : 0.015m
Offset: 115.491m
S-O dHA 5 16 17
Fill: 1.541
MEAS OK
Define/Mid PT
Pt# J5
Np: 3.027
Ep: -0.685
Zp: 0.305
READ R E C MEAS OK