Stonex R80 Robotic Total Station - User Manual 48
Collimate prism in target point P1, where instrument will be
transferred. Meantime click [Measure] key.
Click [Continue] key and point P1 coordinates are displayed
in the lower left corner of screen.
Click [Save] key. Coordinate of P1 can be ascertained and it
will return to main menu. At last, power off and transfer
instrument to P1 (transfer prism from P1 to P0 meantime).
After instrument is established in P1, enter into traverse
surveying of coordinate measurement thought the [Setup]
button and select “Call” button with stylus.