Stonex R80 Robotic Total Station - User Manual 60
8.2. Plate level
I. Check
1. Mount the instrument on a stable device (as tripod, adjusting device), and fix it.
2. Level the instrument until the plate level is parallel to a line linking leveling foot screws A and B, then adjust
the two screws to center the bubble.
3. Turn the instrument 180°/200gon, observe the moving direction of the bubble, if it is still centered, no
adjustment is necessary, if not, you have to adjust it.
II. Adjustment
1. Mount the instrument on a stable device and fix it.
2. Level it roughly.
3. Turn the instrument and make the tubular level be parallel to
a line linking two leveling foot screws, then adjust the two
screws to center the bubble.
4. Turn the instrument 180°/200gon, adjust the Adj-screw with
adjustment pin slightly to correct half of the bubble’s
displacement when it doesn’t move,
5. Repeat operations 3, 4 until the bubble remains centered in
any position.
8.3. Circular level
I. Check
1. Mount the instrument on a stable device and fix it.
2. Level it accurately by the plate level.
3. Observe the bubble of the circular level, if it is centered, no
adjustment is necessary, if not, you have to adjust it.
II. Adjustment
1. Mount the instrument on a stable device and fix it.
2. Level it accurately by the plate level.
3. Adjust the three adj-screws to center the bubble by a wrench.
NOTE: Be careful when adjusting the three screws, and the tightening tension is identical for them.
Circular Level
Adjusting pin