User Manual

38 Appendix A - Specifications/Dimensions
StorCase Technology, Inc. InfoStation User's Guide - Rev. A01
The following InfoStation specifications and dimensions are provided for reference only.
Appendix A - Specifications/Dimensions
Physical
Specifications
Rack Mount
Tower
Height
6.95" (176.5mm) 19.96" (507.0mm)
Width
16.92" (429.8mm)
8.47" (215.1mm)
(1)
Depth 20.57" (522.5mm) 22.96 (583.2mm)
(1)
Includes base
Environmental Specifications
Operating
Storage
Ambient Temperature 0° C to 50° C -50° C to 75° C
Relative Humidity
(1)
10% to 80% 10% to 90%
Altitude
-1000 to 50,000 ft -1000 to 50,000 ft
-304m to 15240m -304m to 15240m
Shock
(2)
10g 60g
(1)
Non-condensing with maximum gradient of 10% per hour
(2)
11 msec pulse width 1/2 sine wave
Weight
60.8 lbs
(2)
71.0 lbs
(2)
(2)
Weight of empty chassis
Total for 4 Blowers
158 CFM
Cooling
Electrical Specifications (for One Power Supply)
Auto Ranging 400 Watt Power Supply (500W Peak)
AC Input
100 to 120VAC or 200 to 240VAC, 50/60 Hz
DC Output
5V at 21.5 AMPS, 12V at 24.5 AMPS
Chassis Reliability/Maintainability
MTBF
100,000 Hours
MTTR 5 Minutes
Preventive
Maintenance
None
IFS_specs1