StorCase® Technology Data Express® DE100i-S Removable SCSI Narrow Single-Ended Drive Enclosure User's Guide
i StorCase® Technology Data Express® DE100i-S Removable SCSI Narrow Single-Ended Drive Enclosure User's Guide Part No. D89-0000-0001 H00 December 2002 StorCase Technology, Inc. 17600 Newhope Street Fountain Valley, CA 92708-9885 Phone (714) 438-1850 Fax (714) 438-1847 DE100i-S User's Guide - Rev. H00 StorCase Technology, Inc.
ii LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free from defects in material and workmanship, subject to the conditions and limitations set forth below. StorCase will, at its option, either repair or replace any part of its product that proves defective by reason of improper workmanship or materials.
iii Free Technical Support StorCase provides free technical support. If you experience any difficulty during the installation or subsequent use of a StorCase product, please contact StorCases Technical Support Department prior to servicing your system. This warranty covers only repair or replacement of defective StorCase products, as described above. StorCase is not liable for, and does not cover under warranty, any costs associated with servicing and/or installation of StorCase products.
iv Declaration of Conformity Company Name: StorCase Technology, Inc.
v Table of Contents INTRODUCTION ..................................................................................................................... Packaging Information .................................................................................................. Serial Numbers .............................................................................................................. Package Contents ................................................................................................
vi List of Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Package Contents .......................................................................................... 2 DE100i-S Receiving Frame and Drive Carrier ............................................... 3 Receiving Frame Front Panel ......................................................................... 4 Receiving Frame Unit ID Number and Activity Display ....................
Introduction 1 DATA EXPRESS® DE100i-S INTRODUCTION Packaging Information The StorCase Technology Data Express® system is shipped in a container designed to provide protection and prevent damage during shipment. The Data Express unit was carefully inspected before and during the packing procedure at the factory. Bent or broken connectors, or evidence of other damage to the Data Express should be reported to the shipper immediately. Refer to Figure 1 for the package contents.
2 Introduction Package Contents The DE100i-S package contents include the following items. If any item is missing or damaged, contact your StorCase dealer for a replacement. 1 2 8 7 9 3 Da Disk (No Driv t Incl e ude d) 4 6 ta E xpr ess Cab Cov (Pro er le vide d) Pow er I/O Cab Cable ID le Sele ct Cab Driv le e Car rier Driv Har e Phil 3/16 lipsdwareMountin Flat # 6-32(4ea g HD x ) 0151 Cab Scre le # Flat 6-32 ws (2Cover HD x 3/16plcs ) 0430 5 1. 2. 3. 4. 5. 6.
Introduction 3 General Description The StorCase Technology Data Express® DE100i-S is a removable drive carrier and receiving frame designed to provide durable and reliable mounting for one (1) 3.5 SCSI Narrow drive within 5.25" half-height peripheral slots (Figure 2). The DE100i-S allows a drive to be removed and transported to another DE100i-S-equipped computer or expansion chassis, and also provides the ability to secure sensitive data by removing and storing the drive safely for future use.
4 Introduction Receiving Frame Front Panel (Figure 3) Key Lock/Drive Power Switch: Performs three functions. The key lock assures proper seating of the device carrier within the receiving frame, turns power to the device carrier on and off, and prevents unauthorized removal or installation of the carrier. For the computer to access data on the DE100i-S disk drive, the key must be turned counterclockwise to the locked position.
Introduction 5 Figure 4: Receiving Frame Unit ID Number and Activity Display Receiving Frame Rear Panel (Figure 5) DC Power Connector (J3): The Data Express uses a standard 4-pin DC Power Connector to accept DC power. I/O Connector (J2): The input/output connector provides a standard interface for all SCSI signals. See Table 2 for J2 pin assignments. ID Select Pins (J4): Pins 1-14 are reserved.
6 Introduction Reserved Enable Termination Power To/From SCSI Bus W3 W1 +12 J3 Disable Onboard Termination +5 GND 19 20 13 1 14 2 ID0 ID1 ID2 Ground Remote ID Select W2 J6 A B 12 12 6 J6: P1, P2 = Enable Spin Down/Up Timer (Installed at Factory) P4, P6 = Remote Drive Activity P3, P5 = Reserved J6A DC Power Connector J6A: P1 P2 P3, P5 P4, P6 6 J2 J4 = = = = Write Protect Fault Not Used Ground 0408 Reserved Installed at Factory P4 Anode I/O Connector P6 Cathode = Pin 1 Figure
Installation 7 INSTALLATION Installing the Drive into the Carrier Preparation While performing the steps in this section, work on a soft surface to prevent excessive shock to the drive being installed. Also refer to the manufacturer's documentation provided with the drive. NOTE: A #2 Phillips screwdriver will be required during this procedure. 1. Remove the drive from its protective packaging. 2. Plastic Drive Bezel: If the drive came equipped with a plastic front bezel, it must be removed. 3.
8 Installation Installation 1. Attach the I/O cable from the rear distribution board of the DE100i-S carrier to the disk drive (Figure 6). 2. Attach the 4-pin DC power cable from the rear distribution board to the disk drive (Figure 6). 3. Install the 4-pin ID select cable into the rear signal distribution board connector and connect to the appropriate drive pins as shown in Figure 7. 4. Carefully insert the drive into the carrier at an angle, cable-end first.
Installation 9 SCSI ID Select Cable Connection Black Brown Red Yellow - Connects Connects Connects Connects to ID0 pin on drive to ID1 pin on drive to ID2 pin on drive to Drive Activity Signal pin on drive Drive Carrier Board ID Select Cable 2mm Drive Connectors Black (ID0) Brown (ID1) Red (ID2) Yellow (Drive Activity) 0175B Drive Carrier Figure 7: Typical SCSI ID Select Connection DE100i-S User's Guide - Rev. H00 StorCase Technology, Inc.
10 Installation Installing the Receiving Frame The drive should be installed into the carrier before installing the receiving frame into the mounting bay of a computer or expansion chassis. NOTE: Use a #2 Phillips screwdriver during this procedure. 1. Turn OFF power to the computer. 2. Open the computer system according to the manufacturers instructions. If necessary, temporarily remove any expansion boards that may make installation difficult. 3.
Installation 11 IMPORTANT NOTE: In order to use remote ID selection from a computer or expansion chassis, the Unit ID number on the DE100i-S receiving frame must be set to "0" with the provided alignment tool. Refer to the section "Selecting the Unit ID Number" later in this User's Guide for the Unit ID selection procedure. 4. With the drive carrier locked in place inside the receiving frame, install the DE100i-S into the 5.25 drive opening in the computer or expansion chassis.
12 Installation 8. Connect the power cable from the DC power supply in the computer or expansion chassis to the power connector on the DE100i-S receiving frame. Refer to Figure 5 for the receiving frame power connector location. 9. Replace any expansion boards that may have been removed earlier. Replace the system cover according to the manufacturers instructions. 10. Reconnect any system or peripheral cables removed earlier. 11. Turn ON power to the computer.
Installation 13 4. Use the alignment tool supplied with the DE100i-S to select the unit ID number of the disk drive. Refer to Figure 10 for the location of the Unit ID Select Switch inside the receiving frame. 5. After selecting an appropriate unit ID number, replace the DE100i-S carrier in the receiving frame, and LOCK IT IN PLACE. NOTE: 6. The lock on the DE100i-S receiving frame functions as a lock and a DC power switch for the carrier unit.
14 Installation SCSI Interface Connector J2 The SCSI interface connector (J2) pin assignments are supplied for your convenience. All odd numbered pins, except Pins 25 & 29 must be connected to ground. Pin 25 should be left open. Pin 29 can be used for Synchronized Spindle operation. Pin 26 is reserved for terminator resistor power source.
Appendix A - Specifications/Dimensions 15 APPENDICES DE100i-S User's Guide - Rev. H00 StorCase Technology, Inc.
16 Appendix A - Specifications/Dimensions Appendix A - Specifications/Dimensions SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI) Standard set by the American National Standards Institute (ANSI).
Appendix A - Specifications/Dimensions Receiving Frame with Carrier 2.06 (52.3mm) 17 3.13 (79.5mm) 0.50 (12.7mm) #6-32 x 8 0.38 (9.7mm) 1.70 (43.2mm) 5.75 (146.1mm) Isolator Board 8.18 (207.8mm) Isolator Board DE100 Board 5.50 (139.7mm) 0.25 (6.4mm) 3.13 (79.5mm) 0.15 (3.8mm) #6-32 x 4 Bottom 0.64 (16.3mm) Carrier Only 1.68 (42.7mm) 7.38 (187.5mm) 3.75 (95.3mm) 4.67 (118.6mm) 1.75 (44.5mm) 0.25 (6.
18 Appendix B - Factory-Installed Options Appendix B - Factory-Installed Options Hot Swap Board The SCSI Hot Swap Board allows the installation, removal or exchange of DE100i-S carriers while your computer system is operating by monitoring and protecting the computer system and other peripheral devices on the SCSI Bus. The Hot Swap option eliminates the need to shut down your system when adding or removing a SCSI device by performing two functions: 1.
Appendix B - Factory-Installed Options 19 Figure B-1: Attaching the Hot Swap Board Jumper Options The jumper pins on the Hot Swap Board are similar to those on the SCSI Data Express motherboard. Removing the jumper at location JP1 will enable onboard receiving frame termination (Figure B-2). Location W1 provides remote ID selection. Jumper J4 Pins 4 and 6 provide a signal to drive remote activity LED logic (Pin 4 = Anode, Pin 6 = Cathode).
20 Appendix B - Factory-Installed Options Figure B-2: Hot Swap Board Jumper Options 3. As the unit number flashes, the Hot Swap Board monitors the activity of the SCSI bus. When activity is no longer present, the Hot Swap Board will remove power from the drive and then remove the device from the SCSI Bus. The unit number will continue to flash during this period. 4.
Appendix B - Factory-Installed Options 21 Carrier Installation Follow the procedures below to install the DE100i-S drive carrier into the receiving frame equipped with the Hot Swap option. 1. Install the carrier into the receiving frame. A "u" will be present on the front panel, indicating that the carrier is in an unlocked condition. 2. Turn the key lock mechanism, located on the front of the receiving frame, counter clockwise to the ON position.
22 Appendix B - Factory-Installed Options Solenoid Drive Lock The factory installed solenoid option prevents premature removal of the carrier and drive unit until the target drive has fully spun down. For disk drives, this period of time can range from 15-40 seconds, depending on the type of drive being used (e.g. Barracuda drives require up to 50 seconds). Refer to the drive manufacturer's documentation for specific drive information.
Appendix C - Optional User Configurations 23 Appendix C - Optional User Configurations Attaching the ON/OFF Key to Non-Solenoid Units The following information will provide the necessary steps to attach the ON/OFF key to the key/lock mechanism so that it is non-removable. This configuration is preferred for some applications and is reversible. 1. Verify that power to the receiving frame is OFF. Locate the rectangular shaped key lock mechanism access hole on the inside of the receiving frame.
24 Appendix C - Optional User Configurations DAT Drive SCSI ID Cable Connection The following information applies to the Data Express DE150i-CSD front-loading device carrier. The procedure for installing a DAT drive into the open front carrier is almost identical to that required for disk drive installation in an enclosed drive carrier. The ID Select Cable provided for DAT drives is slightly different than the cable used for disk drives.
Appendix C - Optional User Configurations RED (ID 2) SCSI Termination (Jumper Installed at Factory) BROWN (ID 1) BLACK (ID 0) 25 ID Select Cable (from carrier signal distribution board) N/C .1" ID SELECT PINS I/O Connector 0176 Power Figure C-3: Typical DAT Drive SCSI ID Cable Connection DE100i-S User's Guide - Rev. H00 StorCase Technology, Inc.
26 Appendix D - Optional Accessories Appendix D - Optional Accessories Carrying Case Drive Carrier 0014B S20E104 Carrying Case Figure D-1: Carrying Case The optional molded plastic carrying case is designed to transport the DE100i-S carrier from one site to another in a safe, impact and moisture resistant environment. Its compact dimensions, 7 long x 9 wide x 3.5 high, make it easy to carry and to store. The foam lining is contoured to fit a single Data Express carrier.
Appendix D - Optional Accessories 27 Front Loading Drive Adapter Kit This kit adapts 1" high (3.5" form factor) removable media devices to the StorCase open front Data Express® carrier unit (DE150i-CSD). NOTE: Drive and carrier unit shown are not included with the DX150-KIT. Contact StorCase for ordering information. Figure D-2: DX150-KIT DE100i-S User's Guide - Rev. H00 StorCase Technology, Inc.
28 Appendix D - Optional Accessories Drive Cover 1 Slip Drive Cover Lip into Top Rear of Carrier. The Sides of the Cover Will Fit Between the Drive and the Carrier. Mounting Holes Must be Towards Rear of Carrier. 1 3 Slide Drive Cover Forward Making Certain Front Cover Lip is Inside Carrier. Fasten Screws. 2 Drive Cover 3 2 Swing Drive Cover Down, Covering the Drive. Make Certain You Do Not Damage Connector Pins or Cables.
Appendix D - Optional Accessories 29 Drive Plug 0429 Figure D-4: Drive Plug The drive plug (P/N DX100-PLUG), is designed to fill system or external enclosure bays that are occupied by receiving frames that have no carrier units installed. The purpose of the plug is to provide an attractive and functional method of directing proper air flow to the other installed devices in the system or external enclosure. Contact StorCase for ordering information. DE100i-S User's Guide - Rev.
30 Appendix D - Optional Accessories This Page Left Blank Intentionally. StorCase Technology, Inc. DE100i-S User's Guide - Rev.
Reader's Comments 31 Reader's Comments Please take a few moments when your computer system is up and running to send us your ideas and suggestions for improving our products and documentation.
Reader's Comments CUT ALONG THIS LINE FROM BOTTOM TO TOP OF PAGE 32 FOLD ALONG THIS LINE AND STAPLE SHUT NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES B U S I N E S S R E P LY M A I L FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA POSTAGE WILL BE PAID BY ADDRESSEE TECHNOLOGY CORPORATION 17600 NEWHOPE STREET FOUNTAIN VALLEY CA 92708-9885 StorCase Technology, Inc. DE100i-S User's Guide - Rev.