16 Appendix A - Specifications/Dimensions
Appendix A - Specifications/Dimensions
SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI)
Standard set by the American National Standards Institute (ANSI).
Chassis Reliability/Maintainability
MTBF 500,000 Hours
MTTR 5 Minutes
Preventive
Maintenance None
Electrical Specifications
Input +5V 65mA
+12V 400µA
Environmental Specifications
Operating Storage
Ambient Temperature 0° C to 40° C -40° C to 70° C
Relative Humidity
( 1 )
10% to 80% 10% to 90%
Altitude -1000 to 10,000 ft -1000 to 40,000 ft
-305m to 3048m -305m to 12195m
Shock
(2)
10g 60g
(1)
Non-condensing with maximum gradient of 10% per hour.
(2)
11 msec pulse width 1/2 sine wave.
Physical
Specifications Carrier Receiving Frame
Height 1.68" (42.7mm) 1.70" (43.2mm)
Width 4.67" (118.6mm) 5.75" (146.1mm)
Depth 7.38 (187.5mm) 8.18 (207.8mm)
Weight 1.2lb. (0.55kg) 1.3lb (0.59kg)
(1)
(1)
With carrier removed.