14 Installation
Adjusting the Spin Down/Up Timer
NOTE: The timer for device spin down is controlled by a small selector, located in a cutout
on the side of the DE200 receiving frame as shown in Figure 11. The amount of
time required for a drive to spin down is approximately 15 seconds or more. This
number can vary depending on the type of SCSI device and manufacturer (some
drives may require 45 seconds or more). The factory configuration is set for 20
seconds. A different delay time may be selected with the provided alignment tool.
Refer to the SCSI device manufacturers manual for more information on required
device spin down time.
Figure 11: Device Spin Down/Up Timer Switch
Front of
Receiving
Frame
0143
0
2
4
6
8
A
C
E
0 = 10 SECONDS 8 = 50 SECONDS
1 = 15 SECONDS 9 = 55 SECONDS
2 = 20 SECONDS A = 60 SECONDS
3 = 25 SECONDS B = 65 SECONDS
4 = 30 SECONDS C = 70 SECONDS
5 = 35 SECONDS D = 75 SECONDS
6 = 40 SECONDS E = 80 SECONDS
7 = 45 SECONDS F = 85 SECONDS
Spin Down/Up Time
SCSI Interface Connector J2
The SCSI interface connector (J2) pin assignments are supplied for your convenience. All odd
numbered pins, except Pins 25 & 29 must be connected to ground. Pin 25 should be left open.
Pin 29 can be used for Synchronized Spindle operation. Pin 26 is reserved for terminator resistor
power source.
Pin Signal Pin Signal Pin Signal Pin Signal
2 -Data Bit 0 16 -Data Bit 7 28 -Ground 40 -RST
4 -Data Bit 1 18 -Data Bit P 30 -Ground 42 -MSG
6 -Data Bit 2 20 Ground 32 -ATN 44 -SEL
8 -Data Bit 3 22 Ground 34 Ground 46 -C/D
10 -Data Bit 4 24 Ground 36 BSY 48 -REQ
12 -Data Bit 5 26 TRMPWR 38 ACK 50 -I/O
14 -Data Bit 6
Table 2: SCSI Interface Connector J2 Pin Assignments