ogue Eco Design Installation User Instructions

21
Installation Checklist
2. Essential Information - Multi-fuel Stove
GENERAL
Model:
Vogue Small / Small T
Vogue Midi / Midi T
Vogue Medium Slimline
Vogue Medium
Small
Small T
Midi
Midi T
Medium Slimline
Medium
Nominal Heat Output
Wood kW 5.0 5.0 5.0 5.0 5.0 7.0
Solid Fuel kW 5.0 5.0 5.0 5.0 5.0 7.5
Efficiency
Wood % 80 80 80 78 77 75
Solid Fuel % 80 80 77 78 79 81
CO @ 13% O
2
Wood % 0.14 0.11 0.11 0.12 0.11 0.12
Solid Fuel % 0.07 0.03 0.04 0.11 0.08 0.08
Weight Multi-fuel stove Kg 61.5 76 83 93 101 116
Recommended Fuels
Wood
Seasoned Wood (less than 20% moisture content)
Solid Fuel
Briquette smokeless fuel suitable for closed appliances
(Ancit-Phuracite-Taybrite-Maxibrite-Homefire Ovals)
As tested to the requirements of EN 13240 for intermittent operation
FLUES
Flue/Chimney Size
May be reduced to 128mm (5") if
burning approved smokeless fuels or
burning wood in an appliance approved
for use in a DEFRA smoke control area
Without flue liner Round
(Diameter)
mm ‡153 ‡153 ‡153 ‡153 ‡153 ‡153
inch 6 6 6 6 6 6
Without flue liner system (Square)
mm 135 135 135 135 135 135
inch
With Liner of Factory made system
(diameter)
installed in accordance with
manufacturers instructions
mm 150 150 150 150 150 150
inch 6 6 6 6 6 6
Flue/Chimney
minimum height**
All products
**must be 4.5m from the hearth
to the top of the flue, with
no horizontal sections and a
maximum of 4 bends. Bends
must have angles of less than 45
degrees from the vertical.
m 4.5 4.5 4.5 4.5 4.5 4.5
feet 15 15 15 15 15 15
Flue Draught
Min
Pa
10 10 10 10 10 10
Nominal 15 15 15 15 15 15
Max 20 20 20 20 20 20
Flue Gas Mass Flow
Wood g/s 4.0 4.0 3.8 4.3 5.9 6.5
Solid Fuel g/s 3.4 3.0 3.4 4.0 3.8 4.7
Flue Gas Temperature at Spigot/
Socket
Wood
o
C 283 272 312 303 272 329
Solid Fuel
o
C 297 307 338 278 261 312
Flue Outlet Size
(Top or Rear Option)
All
mm 128 128 128 128 153 153
inch 5 5 5 5 6 6
European Min Spec for Chimney Flue - T400 N2 D 3 G50
VENTILATION
A) Traditionally Built Homes
• Where leakage is greater than 5m
3
/hour/m
2
.
• Ventilation normally required = 550mm
2
per kW output over 5kW
B) Modern Construction Homes
• Where leakage is less than 5m
3
/hour/m
2
.
• Ventilation normally required = 550mm
2
per kW
Wood
Solid
Fuel
A Additional Ventilation
mm2 None None None 1100 1650
cm2 None None None 11 16.5
in2 None None None 1.77 2.6
B Additional Ventilation
mm2 2750 2750
2750 3850 4400
cm2 27.5 27.5 27.5 38.5 44
in2 4.4 4.4 4.4 6.2 7.1
For full technical details on ventilation see Technical Appendix on Page 46