ogue Eco Design Installation User Instructions

22
Installation Checklist
2. Essential Information - Wood Burning Stove
GENERAL
Model:
Vogue Small / Small T
Vogue Midi / Midi T
Vogue Medium Slimline
Vogue Medium
Small
Small T
Midi
Midi T
Medium Slimline
Medium
Nominal Heat Output Wood kW 5.0 4.8 5.0 5.0 5.0 7.5
Efficiency Wood % 81 78 78 80 76 76
CO @ 13% O
2
Wood % 0.11 0.11 0.09 0.12 0.14 0.10
Weight Wood Kg 68 74 83 91 98 113
Recommended Fuels
Wood
Seasoned Wood (less than 20% moisture content)
As tested to the requirements of EN 13240 for intermittent operation
FLUES
Flue/Chimney Size
May be reduced to 128mm (5") if
burning approved smokeless fuels
or burning wood in an appliance
approved for use in a DEFRA smoke
control area
Without flue liner Round (Diameter)
mm ‡153 ‡153 ‡153 ‡153 ‡153 ‡153
inch 6 6 6 6 6 6
Without flue liner system (Square)
mm 135 135 135 135 135 135
inch
With Liner of Factory made system
(diameter)
installed in accordance with
manufacturers instructions
mm 150 150 150 150 150 150
inch 6 6 6 6 6 6
Flue/Chimney
minimum height**
All products
**must be 4.5m from the hearth to
the top of the flue, with no horizontal
sections and a maximum of 4 bends.
Bends must have angles of less than 45
degrees from the vertical.
m 4.5 4.5 4.5 4.5 4.5 4.5
feet 15 15 15 15 15 15
Flue Draught
Min
Pa
10 10 10 10 10 10
Nominal 15 15 15 15 15 15
Max 20 20 20 20 20 20
Flue Gas Mass Flow Wood g/s 3.9 4.5 4.6 4.7 5.9 7.1
Flue Gas Temperature at Spigot/
Socket
Wood
o
C 268 270 284 265 273 310
Flue Outlet Size
(Top or Rear Option)
All
mm 128 128 128 128 153 153
inch 5 5 5 5 6 6
European Min Spec for Chimney Flue - T400 N2 D 3 G50
VENTILATION
A) Traditionally Built Homes
• Where leakage is greater than 5m
3
/hour/m
2
.
• Ventilation normally required = 550mm
2
per kW output over 5kW
B) Modern Construction Homes
• Where leakage is less than 5m
3
/hour/m
2
.
• Ventilation normally required = 550mm
2
per kW
A Additional Ventilation
mm2 None None None 1650
cm2 None None None 16.5
in2 None None None 2.6
B Additional Ventilation
mm2 2750 2750 2750 4400
cm2 27.5 27.5 27.5 44
in2 4.4 4.4 4.4 7.1
For full technical details on ventilation see Technical Appendix on Page 46
In the U.K. Additional information covering the
installation of the appliance may be found in the
following British Standards: BS EN 15287,
BS EN 1856-2:2009, BS8303.