ogue Eco Design Installation User Instructions
23
Installation Checklist
† England and Wales – Document J / Scotland -
Part F/Document J (Republic of Ireland only)
4. Clearances
4.1 When installing a Vogue stove it is important to observe the following clearances to both combustible and non-combustible materials.
Also ensure that a clearance of 1 meter is maintained in front of the appliance when operating.
IMPORTANT: INSTALLATION MUST COMPLY WITH CURRENT BUILDING REGULATIONS.
ENSURE THAT SUFFICIENT CLEARANCES ARE PROVIDED BETWEEN THE FLUE PIPE AND ANY COMBUSTIBLE
MATERIALS IN THE FIREPLACE IN ACCORDANCE WITH THE RULES IN FORCE.
†
Non-Combustible Materials
4.2 All appliances will require some clearance between them and any non-combustible materials to allow for either:
— Installation, servicing or accessing controls.
— Convection in order for the appliance to function properly.
Recommended: Minimum clearances for installation/servicing/convection is:
Rear - 25mm Sides - 50mm Top - 100mm
NOTE: If the non-combustible surface is less than 200mm thick additional clearances may be required.
This requirement ensures that the non-combustible material does not transmit excessive heat through the wall onto combustible
material which might be placed against it.
See Diagrams 3 and tables.
3. Minimum Dimensions - Hearth
3.1 Wood Models
These appliances can stand on a superficial hearth which is
a minimum of 12mm thick, see Diagram 1.
This is also referred to as a Floor Protector Plate or Floor
Protector.
3.2 Multi-Fuel Models
When installed on a plinth these appliances do not raise
the floor temperature enough to require a constructional
hearth. These appliances can stand on a superficial hearth
which is a minimum of 12mm thick, see Diagram 1. This is
also referred to as a Floor Protector Plate or Floor Protector.
When installed without a plinth these appliances must
stand on a non-combustible constructional hearth which is at
least 125mm thick with the minimum dimensions as shown
in Diagram 2.
Hearth construction must comply with the building
regulations in force.
3.3 All Models
If this appliance is installed in an elevated setting it is
recommended to increase the 225mm hearth depth to safely
contain any falling logs or embers. The higher the appliance
is installed the deeper the hearth should be to avoid
scorched floor coverings.
Small
Models
Midi
Models
Medium Slimline
Models
Medium
Models
A 709mm 734mm 685mm 759mm
2
225mm minimum
500mm minimum
125mm
12mm
150mm
minimum
150mm min
150mm min
B
840mm
minimum
Constructional Hearth
Appliance
Decorative Hearth
Change in level to
mark safe perimeter
1
225mm minimum
12mm
150mm
minimum
150mm min
150mm min
A
840mm
minimum
Appliance
Decorative Hearth
Change in level to
mark safe perimeter
Small
Models
Midi
Models
Medium Slimline
Models
Medium
Models
A 984mm 1009mm 960mm 1034mm