ogue Eco Design Installation User Instructions
25
Installation Checklist
Note: Minimum distance to combustible material must be 450mm from any exposed single wall flue pipe.
5. Optional Extras
Outside Air Kit
5.1 This appliance can be fitted with an optional kit to help bring
air directly into the appliance from outside. For installation
and operating procedures refer to the instructions supplied
with the Outside Air kit - Stovax Part No PM1323.
Appliance Part No.
Small / Small T SMAIR-E
Midi / Midi T MIDAIR-E
Medium Slimline MEDSLAIR
Medium MEDAIR-E
Heat Shield
5.2 Thisappliancecanbettedwithaheatshieldinorderto
decrease the distance the appliance can be installed from
a wall. This must be done at the time of installation.For
installation and operating procedures refer to the instructions
supplied with the heat shield - Stovax Part No PM1347.
Appliance Part No.
Small / Small T VG-SMHSK-E / VG-SMTHSK-E
Midi / Midi T VG-MIDHSK-E / VG-MIDTHSK-E
Medium Slimline VG-MEDHSK-E
Medium VG-MEDHSK-E
Woodburning Conversion Kit
5.3 Theappliancecanbettedwithanoptionalkitwhichaids
Multi-Fuel stoves with the continual burning of wood. The
kit focuses primary air to the centre of the appliance which
helpstoestablishaameandreplicatestherecommended
conditions for burning wood.
For details on purchasing a Woodburning Conversion kit for
this appliance contact your retailer.
Appliance Part No.
Small / Small T WDKITSM
Midi / Midi T WDKITMID
Medium Slimline WDKITMEDSL
Medium WDKITMED
Distance to Combustible Materials - Parallel Position
Model Flue Configuration
Woodburning Multi-fuel
D (side) E (Rear) D (side) E (Rear)
Vogue Small
Single Wall - Without a Heat Shield
400 400 400 450
Vogue Small T
Single Wall - Without a Heat Shield
400 400 350 400
Vogue Midi
Single Wall - Without a Heat Shield
400 500 375 375
Vogue Midi T
Single Wall - Without a Heat Shield
400 500 400 400
Vogue Medium Slimline
Single Wall - Without a Heat Shield
250 300 350 500
Vogue Medium
Single Wall - Without a Heat Shield
450 500 450 550
Distance to Combustible Materials - Corner Position
Model Flue Configuration
Woodburning Multi-fuel
D (side) D (side)
Vogue Small
Single Wall - Without a Heat Shield
400 400
Vogue Small T
Single Wall - Without a Heat Shield
400 350
Vogue Midi
Single Wall - Without a Heat Shield
400 375
Vogue Midi T
Single Wall - Without a Heat Shield
400 400
Vogue Medium Slimline
Single Wall - Without a Heat Shield
250 500
Vogue Medium
Single Wall - Without a Heat Shield
450 450