ogue Eco Design Installation User Instructions

35
Installation Instructions
6. Smoke Control Setting
Wood Burning Stove
Woodburning appliances are supplied with a
pre-tted smoke control setting and has been
independently tested to PD6434 making them
exempt from the controls that generally apply in
Smoke Control Areas.
THE SMOKE CONTROL FACILITY IS SUPPLIED
DISABLED AND MUST THEREFORE BE MODIFIED
BEFORE INSTALLATION, IN ORDER FOR THE
APPLIANCE TO MEET THE REQUIREMENTS OF A
SMOKE CONTROL AREA AND MUST BE OPERATED
CORRECTLY IN ORDER TO MINIMISE THE AMOUNT
OF SMOKE PRODUCED.
If this appliance is installed outside of a Smoke
Control Area then the Smoke Control setting can be
left disabled to give more control over the lower burn
rates.
Any modifications to the setting should only be
done by a suitably qualified installer and must be
done at the time of installation.
6.1 This appliance is suitable for use in a Smoke Control
Area when burning wood and following the instructions
for use specified in this manual but ONLY if the Smoke
Control setting has been enabled.
MODIFICATION WILL NEED TO BE CARRIED OUT
PRIOR TO INSTALLATION OF THE APPLIANCE.
6.2 To access the Smoke Control setting, carefully tip the
appliance onto its back.
6.3 When the Smoke Control setting is disabled the stub points
downwards, see Diagram 22 A.
The appliance cannot be used in a Smoke Control Area.
22
Smoke Control setting
B. ENABLED
A. DISABLED
6.4 Twist the stud 90º either way to enable the Smoke Control
setting, see Diagram 22 B.
6.5 Tighten the nut to secure.
The appliance can now be used in a Smoke Control Area.
Multi-Fuel Burning Stove
Multi-fuel appliances are supplied with an additional
slide restrictor plate making them exempt from
the controls that generally apply in Smoke Control
Areas.
THIS PLATE IS SUPPLIED SEPARATELY AND
THE APPLIANCE MUST BE MODIFIED BEFORE
INSTALLATION, IN ORDER TO MEET THE
REQUIREMENTS OF A SMOKE CONTROL AREA
AND MUST BE OPERATED CORRECTLY IN ORDER
TO MINIMISE THE AMOUNT OF SMOKE PRODUCED.
If this appliance is installed outside of a Smoke Control
Area then there is no need to fit the supplied plate.
Any modifications to the setting should only be
done by a suitably qualified installer and must be
done at the time of installation.
This section applies to the Vogue products listed:
Product Code Appliance
VG-SMM-E Vogue Small Multi-Fuel
VG-SMTM-E Vogue Small T Multi-Fuel
VG-MIDM-E Vogue Midi Multi-Fuel
VG-MIDTM-E Vogue Midi T Multi-Fuel
VG-MEDSLM-E Vogue Medium Slimline Multi-Fuel
VG-MEDM-E Vogue Medium Multi-Fuel
6.6 The Vogue models listed are supplied with a smoke control
kit and have been independently tested to PD6434 making
them exempt from the controls that generally apply in Smoke
Control Areas.
6.7 These models are suitable for use in a Smoke Control Area
when burning wood and following the instructions for use
speciedinthismanualbutONLYiftheSmokeKithasbeen
tted.
6.8 Iftted,theSmokeControlkitisattachedtothefrontofthe
appliance via 4 screws, see Diagram 23.
23
This will ensure the air controls cannot be shutdown &
the appliance operates in a manner that conforms to the
emissions standards for a Smoke Control Area.