Weight Calibration Afterthesuccessfulinstallationofprintheads,thewizardbeginsthe
weighttest,inwhicheachheadprintsasample.Thistesttakes15–25
minutes.
Figure 7-61: Weight test progress screen
14. Carefullyremovethesamplesforeachhead,keepingtrackofthehead
thatprintedthem.
Figure 7-62: Samples printed on the Alaris printer build tray
15. Usingthescale,weigheachsampleandentertheweight(ingrams)for
thecorrespondingheadinthewizardscreen.
16. Closetheprintercover,thenclick
Next.
Figure 7-63: Weight Test data entry screen
Support Print Head Model Print Head