4. Inthenextwizardscreen,observethenumbersandwaituntilthelevel
isrelativelystable—twounitsaboveorbelowtheaveragelevelshown.
Figure 7-67: Load cell calibration screen
5. SelecttheWeightisstablecheckbox,andclickNext.
Ifyouneedtocalibratemorethanoneloadcell,thenextcalibration
screenappears.Repeatsteps4and5untilalloftheloadcellsare
calibrated.
6. Click
Doneinthefinalwizardscreen.
Figure 7-68: Final wizard screen
If you removed the waste container, make sure to replace it with its metal
cover, and make sure that the drain tube is not bent. Operating the printer
without the waste-container cover results in an inaccurate measurement of
the waste weight, which will cause waste to overflow into the printer.