User's Manual

Operating & Maintaining the Stratasys P750K 3D Printer
6–36 DOC08010 Rev. A (DRAFT 1)
Note: To accurately test and calibrate print heads, they must be clean. If
necessary, run the Head Cleaning wizard before beginning this
procedure.
To test and calibrate the print heads:
1. Prepare—
disposableȱcleaningȱglovesȱ(anyȱclean,ȱpowderȬfreeȱprotectiveȱ
gloves)
pinkȱpaper
theȱMissingȱNozzlesȱruler
theȱscaleȱsuppliedȱforȱuseȱwithȱthisȱwizard
Note:Ensure that the scale is calibrated and charged before beginning
this procedure.
2. StartȱtheȱHeadȱOptimizationȱwizardȱfromȱtheȱOptionsȱmenu.
Figure 6-48: Starting the Head Optimization wizard
3. Inȱtheȱopeningȱwizardȱscreen,ȱclickȱNextȱtoȱbegin.
TheȱWizardȱConditionsȱscreenȱappears.
4. Readȱtheȱconditions,ȱselectȱIȱAgreeȱandȱclickȱ
Next.