User's Manual

DOC08010 Rev. A (DRAFT 1) 6–61
Stratasys P750K User Guide
Replacing the
Odor Filter
Ifȱtheȱprinterȱexhaustȱisȱnotȱconnectedȱtoȱanȱexternalȱventilationȱsystem,ȱaȱ
builtȬinȱactivatedȬcarbonȱfilterȱremovesȱodorsȱfromȱprintingȱmaterials.ȱThisȱ
filterȱshouldȱbeȱreplacedȱregularlyȱ(asȱnecessary)ȱtoȱkeepȱyourȱworkingȱ
environmentȱpleasant.ȱThisȱisȱnormallyȱdoneȱduringȱtheȱpreventiveȬ
maintenanceȱserviceȱvisit.
Replacing the
UV Lamps
TheȱUVȱlampsȱusedȱforȱcuringȱmodelsȱhaveȱaȱlong,ȱbutȱlimited,ȱworkingȱ
life.ȱTheȱStratasysȱserviceȱengineerȱtestsȱtheirȱeffectivenessȱduringȱregularȱ
maintenanceȱchecks,ȱandȱreplacesȱthem,ȱifȱnecessary.ȱYouȱcanȱtestȱandȱ
adjustȱtheirȱeffectiveȱpowerȱwithȱtheȱUVȱCalibrationȱwizardȱ(seeȱ“Testingȱ
andȱCalibratingȱtheȱUVȱLamps”ȱon
ȱpage 53.ȱIfȱyouȱneedȱtoȱreplaceȱaȱUVȱ
lamp,ȱfollowȱtheseȱinstructions:ȱ
1. Makeȱsureȱtheȱprinterȱisȱinȱofflineȱmode.
Figure 6-98: Offline mode indicator (red)
Theȱonline/offlineȱbuttonȱatȱtheȱbottomȱofȱtheȱprinterȱinterfaceȱshouldȱbeȱ
red.ȱIfȱnot,ȱclickȱitȱtoȱswitchȱtheȱprinterȱtoȱofflineȱmode.
2. StartȱtheȱUVȱLampȱReplacementȱwizardȱfromȱtheȱOptionsȱmenuȱ(seeȱ
figure 6Ȭ8ȱonȱpage 11).ȱ
3. Makeȱsureȱthatȱtheȱbuildȱtrayȱisȱempty,ȱandȱconfirmȱthisȱinȱ
theȱwizardȱ
screen.ȱThen,ȱcloseȱtheȱprinterȱcoverȱandȱclickȱ
Next.
Figure 6-99: “Empty tray” confirmation screen
Theȱaxesȱmoveȱtoȱtheȱ“home”ȱposition.
WARNING: Before continuing, make sure that the safety interlock is not
defeated, and that the lamp is not hot.