User's Manual Part 4

STRATEGIC Technologies Inc. Individual Status Log Repor
t
Individual Status Log Report
When a PRU+ calls the Central Computer (CC) the transferred information is stored in an Individual
Status Log on the CC. Each participant has a unique ID that is used to identify the participant. The
report will indicate all activity of the participant.
The Events generated by the PRU+ are recorded as follows:-
Events
Event Type Description
..info sch. call Info The PRU+ made a scheduled call
..info cc busy Info The PRU+ called the CC, but the line was busy
..info no dialtone Info The PRU+ attempted a call, but the line was off-hook
..info no connect Info The PRU+ dialled but did not connect to the CC
..info comm error Info The PRU+ connected to the CC but the call was
interrupted or terminated by excessive line noise
ALARM NO AC Alarm The PRU+ was disconnected from AC power
.cont no ac Cont Indicates a continuing disconnection from AC power
..info ac ok Clear AC power was restored to the PRU+
ALARM PRU CASE OPEN Alarm The PRU+ case has been opened or severely
damaged.
.cont pru case open Cont Indicates a continuing tamper condition
..info pru case ok Clear The PRU+ case has been closed or corrected
ALARM TEL DISC Alarm The PRU+ was disconnected from the telephone line
..info tel conn Clear The PRU+ was reconnected to the telephone line
ALARM TAMPER/SEVER Alarm The PID strap has been completely cut or not reset
.cont tamper/sever Cont Indicates a continuing strap sever
..info tmp/sever ok Clear The strap circuitry has been reset with LOCK again
ALARM PIU/PID TAMPER Alarm The PID strap has been partially cut or tampered with
.cont piu/pid tamper Cont Indicates a continuing strap tamper
..info piu/pid tmp ok Clear The strap circuitry has been reset with a LOCK again
ALARM PID CASE OPEN Alarm The PID’s case has been opened
.cont pid case open Cont Indicates a continuing pid case open
..info pid case ok Clear The case has been closed
ALARM LOW PIU/PID BAT Info The PID battery is low or improperly installed
.cont low piu/pid bat Cont Indicates a continuing low pid battery
..info piu/pid batt ok Info The PID is indicating the low battery has been
corrected
ALARM LOW PRU BATT Alarm The battery in the PRU+ is low. The PRU+ will stop
monitoring unless it is plugged into AC power.
.cont low pru batt Cont Indicates a continuing PRU+ low battery