User's Manual

AD Plus2.0 User Manual
Page 26 of 66
the first N9M server is supported for remote wakeup;
4. Telephone Wake/SMS Wake: wakes up the MDVR by calling or sending
SMS messages to the device. You need to set the mobile number to wake up
the device in advance.
Power Box
Choose Preferences > Basic Setup > Time Setup > Power Box. The displayed
screen is as shown in the following figure:
Set the shutdown and wake-up thresholds controlled by the power box
1. Shutdown Distance: When ACC is disabled and the vehicle movement
distance is less than the configured threshold, the device is shut down. The
threshold range is 3 to 20 m, and the default value is 10 m;
2. Wakeup Distance: This parameter is currently not used;
3. Wakeup Threshold: determines whether to wake up the MDVR according to
the acceleration received by the built-in G-Sensor of the power box when the
ACC detects that the movement in any axis exceeds the threshold. It can be set
to 1–1000 mg, 10 mg by default.
The following displays the data on the 3 axes, and the currently detected wakeup
value.
2.6.4. User Setup
Tap Preferences > Basic Setup > User Setup, as shown in the following figure: