User's Manual Part 1

Antenna Placement Warning
Ground Warning
Power Cord Assembly Caution
Battery Caution
Do not locate any antenna near overhead power lines or other
electric light or power circuits, or where the antenna can come
into contact with such circuits. When installing antennas, take
extreme care not to come into contact with such electrical
circuits, as they can cause serious injury or death.
For the correct installation and grounding of antennas, please
refer to national and local codes (for example, US:NFPA 70,
National Electrical Code, Article 810; in Canada: Canadian
Electrical Code, Section 54).
You must ALWAYS install an external grounding wire on the OWS
product. The ground connection must be complete before
connecting power to the OWS enclosure—a simple continuity
check between the enclosure and the ground termination point
can confirm this. Grounding of the OWS must comply with
National Electrical Code (NEC) requirements, unless local codes
in your area take precedence over the NEC code.
An assembled power cord is not supplied with the OWS. The
power cord must be assembled by a professional installer, and the
final assembly must comply with National Electrical Code (NEC)
requirements, unless local codes in your area take precedence
over the NEC code.
The OWS product contains a non-rechargeable, non-user-
serviceable lithium ion battery. Exercise caution to avoid shorting
the terminals of this device.
Consult local laws and regulations for the proper disposal of
batteries in your area.