Product Manual
Page 7 of 10
Key Use:
0~9 - For entering a number (example: the number of samples or unit weight value).
‘ ‘ - For entering the radix point.
ZERO - For ensuring the start weight as zero before weighing.
TARE - For deducting the weight of the vessel on the platform, such as the plate.
NUMBER SET - For ensuring the sample number before entering it.
WEIGHT SET - For ensuring the unit weight before entering it.
CLEAR - For clearing the number or unit weight falsely set.
CHECK - For setting the alarm number.
M+ - For memory accumulation.
CM - For clearing the memory accumulation.
TOTAL - For displaying the memory time accumulation and the total accumulation numbers.
Operation Process:
1. Plug in the power cord or install the batteries. Turn on the power switch and the three displays will
flash the number from 0 to 9 in succession and then back to 0. Then the zero tracking indicator
light will turn on. If the weight is not zero, press the zero tracking key to make it zero.
2. Load the weight on the weighing platform of the scale. The LCD digits will indicate the value of the
weight.
Maintenance
1. Load the weight slowly and evenly on the platform of the scale. Avoid sudden impacts which
could cause sensor damage.
2. Keep the scale clean to ensure the normal operation.
3. Remove the batteries if the scale will be left unused for an extended period of time.