User's Manual

www.stryker.com 6390-009-001 REV B 19
Return To Table of Contents
Select your configuration (see Figure 7, Figure 8, or Figure 9 for reference).
Note: All measurements are shown in inches.
1 Choose one hole to drill Ø 1/2 in (1.3 cm) through for electrical input.
2 Router depth to be 9/16 in (1.4 cm) for the floor plate pocket.
3 Floor plate may be cut shorter to either indicated length.
4 Note: The foot end of the floor plate should be 2-3/4 in (7 cm) from the location where the door sill first drops off.
• Floor plate pocket width will be approximately 2.563 in (6.5 cm).
• Bolts (not included) for the floor plate (select one bolt location from each of the five bolt patterns) are to be 3/8-16
UNC flat head cap screws, ASTM-F835 or SAE grade 8. Each bolt should have a flat washer, lock washer, and nut.
• Each bolt and supporting structure underneath must be able to withstand 2750 lb (998 kg) in upward tension and 600
lb (272 kg) in shear in all horizontal directions.
• Each bolt must be installed with a minimum of 40 ft-lb torque.
• Bolts for the antler and rail clamp plates are to be 3/8-16 UNC socket head cap screws.
Note: Antler and rail clamp plates are optional.
• Choose an unused bolt hole to drill through Ø 9/16 in (1.4 cm) for drain hole toward the foot end. Do not use the
front four drill holes.
• Electrical requirements: 12.8V-15.6V , 15A breaker, 2 conductor 10 AWG cable.
• Ensure that minimum clearance is provided from the captain’s seat. Refer to KKK-A-1822F Federal Specification for
the Star-of-Life Ambulance, section 3.10.4, for further guidance.
• You must install the optional wheel guide (6390-027-000) for Type II ambulances (see page 34).
Figure 7: Power-LOAD Floor Plate with Single Standard Floor Mount Cot Fastener Floor Plate (Optional)
Sill
Sill Edge
4
3
2
1
3
Floor Plate Installation Guidelines