Peripheral Pumps OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions)
MODELS Top Suction End Suction PH 35 TS PH 45 TS PH 35 ES PH 45 ES INDEX . . . . . . . . . . . . . . . . . Page No INDEX . . . . . . . . . . . . . . . . . Page No Application . . . . . . . . . . . . . . . . . . . . . . . . . . Product Description . . . . . . . . . . . . . . . . . . . Limits of Application . . . . . . . . . . . . . . . . . . . Technical Specification . . . . . . . . . . . . . . . . Connections . . . . . . . . . . . . . . . . . . . . . . . . Siting of the Pump/Pipework . . . . . . . . .
PRODUCT DESCRIPTION Motor: Induction type, totally enclosed fan ventilated cooling*, continuously rated*, class ‘F’ insulation. Motors comply with IEC34-1. Single phase versions incorporate a permanent capacitor and integral auto resetting thermal overload protection. The standard range of motors are suitable for a supply of 230V, 1 phase, 50Hz. Optional motors are available on certain models to suit various voltages and frequencies (see technical specification for details).
TECHNICAL SPECIFICATION Model Nominal Full Watts Max. Watts Enc. Supply Load Output Consumed Rating (AMPS) (Motor) Duty Rating W H Gross Weight (packed) kg Dimensions (mm) L PH 35 TS 230/1/50 120 380 1.6 IP44 Continuous (S1) @ 209 2.5 l/min & above 130 166 4.8 PH 45 TS 230/1/50 300 540 2.4 IP44 Continuous (S1) @ 238 2.5 l/min & above 130 166 6.2 PH 35 ES 230/1/50 120 380 1.6 IP44 Continuous (S1) @ 241 2.5 l/min & above 130 166 5.0 PH 45 ES 230/1/50 300 540 2.
SITING OF THE PUMP/PIPEWORK WARNINGS: Pump Location If possible site the pump in a location where in the unlikely event of a liquid leak, any spillage is contained or routed to avoid electrics or areas sensitive to liquid damage. Care should be taken to protect the pump from frost and freezing. Ensure pipework to and from pump is independently supported to prevent stress on the pump inlet and outlet branches.
Pump Mounted Above Liquid Source (Suction Lift) The pumps can be used in a suction lift installation providing the height of lift is within the limits specified in the limits of application section. A footvalve and strainer must always be used and the suction pipework size should be 22 mm throughout. Lay the suction piping over the shortest possible distance and ensure there is a constant rise from the liquid source to the pump. Any high spots will cause air pockets to form, reducing system efficiency.
Wiring of connection unit WARNING: This appliance must be earthed.
Supply Cord Replacement: The supply cord and internal wiring within the terminal box are routed and secured to ensure compliance with the electrical standard EN 60335-1. It is essential that prior to any disturbance of this internal wiring, all cable routing and securing details are carefully noted to ensure re-assembly to the same factory pattern is always maintained.
NOISE The equivalent continuous A-weighted sound pressure level from the pumpset does not exceed 70 dB(A) at a distance of one metre. COMMISSIONING WARNINGS: The motor casing can become very hot under normal operating conditions, care should be taken to ensure it cannot be touched during operation. Do not run pump without guards and terminal box lid correctly fitted. The pump chamber must be full of liquid at all times. Seal damage will result if the pump runs dry. 1.
b) Vertical suction models (flooded suction) These models are supplied with priming plugs fitted. Certain models are also available with the pump body rotated. Priming instructions for these variants are as follows:The pump must be primed (filled with liquid) before starting. Turn on liquid supply, prime and vent the pump by unscrewing the priming plug (Figs 7, or 8) slowly until all air escapes and liquid emerges. Re-tighten the plug. Inlet Outlet Priming Plug Outlet Inlet Fig. 7 Fig.
MAINTENANCE WARNINGS: Care should be taken to protect the pump from frost and freezing. Pump Location If possible site the pump in a location where in the unlikely event of a liquid leak, any spillage is contained or routed to avoid electrics or areas sensitive to water damage. 1. No routine maintenance is required but provision should be made for easy access to the pump to allow for repairs due to normal wear and tear. 2. Disconnect electrical supply before working on pump. 3.
TROUBLE SHOOTING GUIDE Symptoms Probable Cause Recommended Action Pump will not start. Electrical supply. Check power to motor. Check the circuit breaker is set. Check the correct fuse is being used. Starter thermal overload tripped. Check overload in starter (if applicable). Investigate cause of problem. Integral motor thermotrip activated. Wait for thermotrip to cool and autoreset. Investigate cause of problem. Air locked. Bleed pipework and pump to clear air. No liquid supply.
YOUR 1 YEAR GUARANTEE Stuart Pumps are guaranteed by Stuart Turner Limited to be free from defects in materials or workmanship for the applicable guarantee period from the date of purchase. The applicable guarantee period is stated in the installation booklet supplied with the pump. Within the guarantee period we will repair, free of charge, any defects in the pump resulting from faults in material or workmanship, repairing, exchanging parts or exchanging the whole unit as we may reasonably decide.
NOTES - 14 -
NOTES - 15 -
DECLARATION OF CONFORMITY 2006/42/EC BS EN ISO 12100-1, BS EN ISO 12100-2, BS EN 809 2006/95/EC BS EN 60335-1, BS EN 60335-2-41 2004/108/EC BS EN 55014-1, BS EN 55014-2, BS EN 55022, BS EN 61000-3-2, BS EN 61000-3-3, BS EN 61000-4-2, BS EN 61000-4-3, BS EN 61000-4-4, BS EN 61000-4-5, BS EN 61000-4-6, BS EN 61000-4-11 1999/519/EC BS EN 62233 2011/65/EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW, COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E.E.C.