Owner's manual

- 12 -
The pump should not be screwed down, ensure anti-vibration feet and flex hoses
are used.
Never operate pump with inlet and/or outlet isolating valves in the closed
position. Damage will occur!
Pump Connections (General)
Fig. 14
22 mm Inlet pipework fed
from water storage system.
22 mm Copper
outlet pipework
Flexible hose
Outlet
Inlet
In the case of horizontal feeds use a 15 mm
compatible stem elbow (not supplied). Do not
bend the hose more than 30° as they may become
damaged, transmit noise or leak.
G ¾ running
nut with captive
sealing washer.
Pump head
Induction
motor
Anti-vibration rubber feet
Single
3
0
°
Max.
permitted
flexible hose
bend.
30°
Do not kink or twist
the hose.
15 mm Flexible pipe with push-
in connections, always ensure
connection is fully pushed
home and that hoses are kept
as straight as possible. Do not
kink or twist the hose.
Do not bend hose more than
30° as they may become
damaged, transmit noise or
leak.
A typical alternative
outlet installation
22 x 15 mm Reducer
22 x 15 mm
Reducer
Integral pump
isolating valve shown
in ‘ON’ position.
15 mm Copper pipe
15 mm Copper
pipe
Open
Close
22 mm Outlet pipework.
22 x 15 mm Reducer
22 mm Elbow
22 mm Copper pipe
15 mm Copper pipe
Outlet
Fig. 15
Outlet
Outlet
Inlet
Inlet
Single
Outlet
Outlet
Outlet
Inlet
Inlet
Inlet
Twin
‘O’-ring
(factory fitted)
Port adaptor
(factory fitted)