Wiring Of Connection Unit
WARNING: This appliance must be earthed.
The wires in the mains lead (supply cord) are coloured in accordance with the following
code:
Green and Yellow: Earth Blue: Neutral Brown: Live
As the colours of the wires in the mains lead of this appliance may not correspond with
the coloured markings identifying the terminals in your connection unit proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the
connection unit which is marked with the letter E or by the earth symbol:
or coloured
green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with
the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter L or coloured red.
Wiring Diagram (Schematic)
The supply cord and internal wiring within the terminal box are routed
and secured to ensure compliance with the electrical standard
EN 60335-1. It is essential that any disturbance of this internal wiring is
avoided and the factory routing and securing of all internal wiring is
always maintained.
Fuses
The following fuse size should be used with the appropriate pump.
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
FLOWSWITCH
REED (S3)
LINK WIRE (BLUE)
BROWN
BLACK
GREEN / YELLOW
BLUE
BROWN
L
S2 S3 S3 S2
E
N
230 VAC/1PH/50Hz
SUPPLY
BLUE
NA
M
N
L
S1 S1
PRESSURE
SWITCH (S1)
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
FLOWSWITCH
REED (S3)
LINK WIRE (BLUE)
BROWN
BLACK
GREEN / YELLOW
BLUE
BROWN
L
S2 S3 S3 S2
E
N
230 VAC/1PH/50Hz
SUPPLY
BLUE
NA
M
N
L
S1 S1
PRESSURE
SWITCH (S1)
PRESSURE
SWITCH (S1)
FLOWSWITCH
REED (S2)
Model Fuse Size (AMPS)
All Models 5
Single Pumps
Fig. 17
Twin Pumps
Fig. 18