Flow Switch Circuit Test
1) To carry out the following test you will need to obtain a magnet.
2) Ensure the power supply is switched on.
3) Position the magnet directly in front of the reed switch box as shown. If pump does
not start, then slowly move the magnet up and down to a position that exceeds the
extent of the reed switch box. The pump should instantaneously start at some point
during this extent of movement. If this does not happen, this indicates a possible
fault with the reed switch or the P.C.B which is located within the terminal box. These
should be checked electrically. Consult Stuart Turner for further instructions.