GOOD PRACTICE
Always flush system prior to installing a new or serviced pump.
Always ensure both sides of the pump are primed (filled with water) before starting the
pump. DO NOT RUN PUMP DRY.
Always ensure the pump has a flooded suction.
Always ensure anti-vibration feet are used.
Ensure pump is sited in dry ventilated position.
Do not allow pump to freeze.
Abide by the Water Supply (Water Fittings) Regulations 1999.
Always ensure pump isolating valves in the inlet and outlet flexible hoses are in the fully
open position.
Ensure earth continuity between suction and delivery pipes.
Always ensure pump wiring conforms with the current national electrical regulations and
installed by a competent person.
Do not install a non-return valve, or devices which
contain non-return valves, in the suction (inlet) pipework
to the pump. The pump must be free to vent to the
supply tanks at all times.
Carefully check pump and pipework for leaks before leaving the installation unattended.