Owner's manual

- 6 -
Single Pump Installation
Cold Water Installations
Before deciding where to locate the unit, check to ensure the static inlet head (Fig. 6)
meets the minimum requirement of 0.5 metres and does not exceed the maximum
requirement stated.
The static outlet head (Fig. 6) must also be within the maximum requirement stated.
Hot Water Installations
The preferred pump location is at floor level next to the hot water cylinder or a level that
is below the secondary tapping that feeds the pump. This will ensure the pump has access
to an air free water supply which is important for trouble free operation (Fig. 7).
Preferred Pump Location
(shaded area). Pump at
a level below the cylinder
draw off tapping.
Max. inlet head 6 m
Min. inlet head 0.5 m
Negative
head
Max. outlet head 6 m
Fig. 6
Max. inlet head 6 m
Min. inlet head 0.5 m
Negative
head
Max. outlet head 6 m
Preferred
area
Fig. 7