StyleCrest Technical Specifications
8
Airflow Data
AIRFLOW (CFM)
MODEL
NUMBER
MOTOR SWITCH
SETTINGS
(0=OFF, 1=ON)
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1 0.2 0.3 0.4 0.5 0.6
1/5 2/6 3/7 4/8 CFM CFM CFM CFM CFM CFM
E7E*-0**H1
0 0 0 0 685  640  606  560  513  460 
1 0 0 0 770  727  692  648  599  552 
0 1 0 0 854  815  779  737  685  645 
1 1 0 0 939  902  865  825  771  737 
0 0 1 0 1,012  974  938  899  850  813 
1 0 1 0 1,084  1,047  1,011  973  930  888 
0 1 1 0 1,157  1,119  1,084  1,047  1,009  964 
1 1 1 0 1,197  1,166  1,130  1,093  1,056  1,017 
0 0 0 1 1,245  1,215  1,178  1,143  1,105  1,066 
1 0 0 1 1,293  1,263  1,225  1,192  1,154  1,114 
0 1 0 1 1,344  1,312  1,278  1,242  1,206  1,169 
1 1 0 1 1,394  1,361  1,330  1,291  1,257  1,223 
0 0 1 1 1,434  1,401  1,369  1,332  1,299  1,267 
1 0 1 1 1,473  1,441  1,408  1,373  1,340  1,311 
0 1 1 1 1,514  1,483  1,451  1,417  1,386  1,355 
1 1 1 1 1,555  1,525  1,494  1,460  1,431  1,398 
NOTES:
1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, and 4. For cooling speeds use COOL switches 5, 6, 7, and 8. 
2. Data is shown with filter
E7E*-0**H1
MAXIMUM HEATING AIRFLOW SETTING
E7EM E7ED E7EU
DOWNFLOW UPFLOW DOWNFLOW UPFLOW
MH RES MH RES MH RES MH RES
10
0001
0101 0001
0101 0101
0101 0101
0101
12 0011
0101
15
010117
20
23 0011 0001 0011 0001 0011
NOTES:
1. MH and Res represent Manufactured Housing and Residential (modular home) applications, respectively
2. To comply with government mandated efficiency standards, speed settings with higher CFM values than listed in this table are not 
allowed in HEAT mode
E7 Airflow Data
Maximum Allowable Heat Settings