StyleCrest Installation Manual

17
3A Fuse
EAC
L 1
L 2
HUM
L 1
L 2
8
1 2 3
4
5 6 7
8
ON
HEAT
COOL
RCGWDY
EHEAT
POWER
ECM BLOWER
DIP Switches
Display Codes
Figure 21. E7 Motor Control Board
Table 7. E7 Electrical Speciļ¬cations
MODEL
NUMBER
E7E*-
SUPPLY
CIRCUIT
TOTAL
AMPERES
MAXIMUM
OVER-
CURRENT
RATING
MINIMUM
CIRCUIT
AMPACITY
010H1 Single 45.3 60 57
012H1
Single 51.6 70 65
Dual "A" 27.8 35 35
Dual "B" 24.2 35 30
015H1
Single 66.1 90 83
Dual "A" 45.3 60 57
Dual "B" 20.8 30 26
017H1
Single 71.1 90 89
Dual "A" 45.0 60 56
Dual "B" 26.1 35 33
020H1
Single 86.9 110 109
Dual "A" 45.3 60 57
Dual "B" 41.7 60 52
023H1
Single 93.6 125 117
Dual "A" 45.3 60 57
Dual "B" 48.0 60 60
NOTE: Wire size must be in accordance to the applicable revision of the
NEC and all other applicable codes.