StyleCrest Installation Manual

Complies with H.U.D. Manufactured Home Construction & Safety Standards.
INSTALLER NAME:
CITY: STATE:
INSTALLATION ADDRESS:
CITY: STATE:
UNIT MODEL #
UNIT SERIAL #
Minimum clearances as shown
in Table 1 (page 3)?
YES NO
Has the owner’s information
been reviewed with the home-
owner?
YES NO
Has the literature package been
left near the furnace?
YES NO
ELECTRICAL SYSTEM
Electrical connections tight? YES NO
Line voltage polarity correct? YES NO
Supply Voltage: ............................................................... VOLTS
Has the thermostat been calibrated? YES NO
Is the thermostat level? YES NO
Is the furnace grounded properly? YES NO
Is the heat anticipator setting
correct?
YES NO
COMBUSTION AIR & VENTING SYSTEM
Is there adequate fresh air supply
for ventilation?
YES NO
Filter(s) secured in place? YES NO
Filter(s) clean? YES NO
INSTALLATION CHECKLIST
Specifications & illustrations subject to change without notice or incurring obligations (06/19).
O’Fallon, MO, © Nortek Global HVAC LLC 2019. All Rights Reserved.
10257240
(NEW)
CONTROL SIGNAL &
MODE
OPERATION TOTAL KW BOARD ACTION
W & Y
AUX HEAT
(Continued)
OFF -
Heat stages off immediately
Blower turns off after 15 second delay
G
FAN
ON - Blower on immediately (35% of COOL)
OFF - Blower off immediately
Y
HEAT PUMP AND COOL
ON - COOL blower on immediately
OFF - COOL blower off after 40 second delay
Y & D
COOL WITH DEHUM
ON -
70% COOL blower on immediately
100% COOL blower after 10 minutes
OFF - COOL blower off after 40 second delay
Table 8. Control Board Operation - Continued