StyleCrest Technical Specifications

5
Anticipator Settings
Service Clearance
For upflow application using upflow stand, 1" minimum per side.
MODEL
NUMBER
E7E*-
SUPPLY
CIRCUIT
TOTAL
AMPERES
MAXIMUM
OVER-
CURRENT
RATING
MINIMUM
CIRCUIT
AMPACITY
010H1 Single 45.3 60 57
012H1
Single 51.6 70 65
Dual "A" 27.8 35 35
Dual "B" 24.2 35 30
015H1
Single 66.1 90 83
Dual "A" 45.3 60 57
Dual "B" 20.8 30 26
017H1
Single 71.1 90 89
Dual "A" 45.0 60 56
Dual "B" 26.1 35 33
020H1
Single 86.9 110 109
Dual "A" 45.3 60 57
Dual "B" 41.7 60 52
023H1
Single 93.6 125 117
Dual "A" 45.3 60 57
Dual "B" 48.0 60 60
ELECTRICAL SPECIFICATIONS
Furnace
Model
Thermostat
Anticipator Setting
010, 012 0.2
015, 017, 020, 023 0.4
ALL MODELS CLOSET ALCOVE
Front ‡ 6” 18”
Back 0” 0”
Sides 0Ӡ 0Ӡ
To p 0” 0”
Top and Sides of Duct 0” 0”
Bottom of Duct 0” 0”
Clearances
NOTE: Wire size must be in accordance to the applicable revision of
the NEC and all other applicable codes.