INSTALLATION GUIDE Induction and Electric Cooktops
Contents Important Note Wolf Induction and Electric Cooktops . . . . . . . . . . . . . 3 To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: Cooktop Specifications . . . . . . . . . . . . . . . . . . . . . . . . 4 Cooktop Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wolf Induction and Electric Cooktops 3 wolfappliance.com/specs Induction and Electric Cooktops IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf factory certified service. Wolf Induction or Electric Cooktop Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
Cooktop Specifications 4 Induction Cooktops OVERALL DIMENSIONS 15" (381) FRAMED 30" (762) FRAMED 36" (914) FRAMED 36" (914) 30" (762) 15" 21" (533) 21" (533) 21" (533) (381) CONDUIT 11/4" (32) 2 1/2" (64) 7/8" (22) ALL SIDES CONDUIT 2 1/2" (64) 7/8" (22) ALL SIDES 11/4" (32) 30" (762) UNFRAMED CONDUIT 7/8" (22) ALL SIDES 11/4" (32) 36" (914) UNFRAMED 21" (533) 21" (533) 36" (914) 30" (762) CONDUIT 11/4" (32) 2 1/2" (64) 3" (76) 7/8" (22) ALL SIDES CONDUIT 11/4" (32) 3" (76)
Cooktop Specifications 5 wolfappliance.
Cooktop Specifications 6 Electrical Requirements Wolf induction and electric cooktops have a 4' (1.2 m) flexible conduit and require a separate, grounded 3-wire electrical supply with its own circuit breaker. Locate the electrical supply within the shaded area shown in the installation illustration for your specific model on the following pages. IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
Cooktop Specifications 7 wolfappliance.com/specs Electrical Requirements IMPORTANT NOTE: For electrical installation, attach the conductors to the residence wiring in accordance with National Electrical Codes and all state, provincial, municipal and local codes. This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes.
Cooktop Specifications 8 Installation Requirements IMPORTANT NOTE: Installation of the induction or electric cooktop must meet location requirements shown in the installation illustration for your specific model on the following pages. All dimensions listed are minimum requirements for safe operation. Wolf induction and electric cooktops are intended for indoor use.
Cooktop Specifications 9 wolfappliance.com/specs 15" (381) Framed Induction and Electric Cooktops STANDARD INSTALLATION SIDE CABINET 30" (762) min COUNTERTOP TO COMBUSTIBLE MATERIALS 13" (330) max 2" (51) TO COMBUSTIBLE* SEE COUNTERTOP CUT-OUT BELOW 18" (457) min 2" (51) TO COMBUSTIBLE* 4 1/2" (114) 36" (914) FLOOR TO COUNTERTOP 15" E (381) 15" (381) SIDE VIEW FRONT VIEW *Minimum clearance from cooktop cut-out to combustible materials up to 18" (457) above countertop.
Cooktop Specifications 10 30" (762) Framed Induction and Electric Cooktops STANDARD INSTALLATION SIDE CABINET 30" (762) min COUNTERTOP TO COMBUSTIBLE MATERIALS 13" (330) max 2" (51) TO COMBUSTIBLE* 18" (457) min 2" (51) TO COMBUSTIBLE* SEE COUNTERTOP CUT-OUT BELOW 4 1/2" (114) 3 1/2" (89) 10" (254) 36" (914) FLOOR TO COUNTERTOP SIDE VIEW E FRONT VIEW *Minimum clearance from cooktop cut-out to combustible materials up to 18" (457) above countertop.
Cooktop Specifications 11 wolfappliance.com/specs 36" (914) Framed Induction and Electric Cooktops STANDARD INSTALLATION SIDE CABINET 30" (762) min COUNTERTOP TO COMBUSTIBLE MATERIALS 13" (330) max 2" (51) TO COMBUSTIBLE* 18" (457) min 2" (51) TO COMBUSTIBLE* SEE COUNTERTOP CUT-OUT BELOW 4 1/2" (114) 3 1/2" (89) 10" (254) 36" (914) FLOOR TO COUNTERTOP SIDE VIEW E FRONT VIEW *Minimum clearance from cooktop cut-out to combustible materials up to 18" (457) above countertop.
Cooktop Specifications 12 30" (762) Unframed Induction and Electric Cooktops FLUSH MOUNT INSTALLATION SIDE CABINET 30" (762) min COUNTERTOP TO COMBUSTIBLE MATERIALS 13" (330) max 2" (51) TO COMBUSTIBLE* 18" (457) min 2" (51) TO COMBUSTIBLE* SEE COUNTERTOP CUT-OUT BELOW 4 1/2" (114) 3 1/2" (89) E 10" (254) 36" (914) FLOOR TO COUNTERTOP SIDE VIEW FRONT VIEW *Minimum clearance from cooktop cut-out to combustible materials up to 18" (457) above countertop.
Cooktop Specifications 13 wolfappliance.com/specs 36" (914) Unframed Induction and Electric Cooktops FLUSH MOUNT INSTALLATION SIDE CABINET 30" (762) min COUNTERTOP TO COMBUSTIBLE MATERIALS 13" (330) max 2" (51) TO COMBUSTIBLE* 18" (457) min 2" (51) TO COMBUSTIBLE* SEE COUNTERTOP CUT-OUT BELOW 4 1/2" (114) 3 1/2" (89) E 10" (254) 36" (914) FLOOR TO COUNTERTOP SIDE VIEW FRONT VIEW *Minimum clearance from cooktop cut-out to combustible materials up to 18" (457) above countertop.
Cooktop Installation 14 Multiple Cooktop Installation Unframed Installations IMPORTANT NOTE: Unframed induction and electric cooktops are not designed to be installed in combination with other cooktops. Unframed induction and electric cooktops can be mounted flush with the top of the countertop or as a frameless installation with the glass-ceramic top mounted on top of the countertop surface. In either installation the countertop cut-out dimensions are the same.
Cooktop Installation 15 wolfappliance.com/specs Unframed Installations FLUSH MOUNT INSTALLATION—OPTION 1 FLUSH MOUNT INSTALLATION—OPTION 2 For this flush mount installation, a recessed area surrounding the standard countertop cut-out is required. Fabrication of the recessed area must take place before the final countertop installation. A template of the countertop cut-out is provided with the unframed cooktop for fabrication purposes.
Cooktop Installation 16 Install the Cooktop Attach the foam strip to the underside of the cooktop frame. Refer to the illustration. For unframed cooktops, be sure to adhere the foam strip to the outer edge of the glass-ceramic top, not the support frame. COOKTOP FRAME Gently lower the cooktop into the cut-out area in the countertop and center. Check that the front edge of the cooktop is parallel to the front edge of the countertop. Check that all required clearances are met.
Cooktop Installation 17 wolfappliance.com/specs Verify Cooktop Operation Cooktop Removal Before operating the induction or electric cooktop, be sure to read the entire use & care guide included with the cooktop for important safety, operating and warranty information. IMPORTANT NOTE: Cooktop removal should only be done by Wolf factory certified service. Clean the glass-ceramic surface as recommended in the induction or electric cooktops use & care guide.
Service Information 18 Troubleshooting Service Information IMPORTANT NOTE: If the induction or electric cooktop does not operate properly, follow these troubleshooting steps: If service is necessary, maintain the quality built into your cooktop by contacting Wolf factory certified service. • Verify that electrical power is being supplied to the cooktop. • Check the electrical connections to ensure that the installation has been completed correctly.
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc.
WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 819062 REV-A 10/ 2011 WOLFAPPLIANCE.COM 800.222.