INSTALLATION GUIDE Warming Drawers
Contents Important Note Wolf Warming Drawers . . . . . . . . . . . . . . . . . . . . . . . . . 3 To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4 Warming Drawer Specifications . . . . . . . . . . . . . . . . . . 8 Warming Drawer Installation . . . . . . . . . . . . . . . . . . .
Wolf Warming Drawers 3 wolfappliance.com/specs Warming Drawer Installation IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf factory certified service. Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference. IMPORTANT NOTE: The warming drawer must be installed with a Wolf stainless steel or integrated drawer front.
Installation Considerations 4 Installation Considerations • The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. Make sure you have the accessory drawer front called for in your installation. Specific installation instructions are included with the drawer front. • For all installations, the warming drawer must be fully enclosed, top and bottom. • The warming drawer platform must be able to support 200 lbs (90 kg).
Installation Considerations 5 wolfappliance.com/specs Combination Installations Electrical Requirements Refer to the illustrations showing combination installations on pages 10–13. Also refer to installation instructions provided with the other Wolf products. The electrical supply should be located as shown in the illustration for your specific installation on the following pages. A separate circuit, servicing only this appliance is required.
Installation Considerations 6 Drawer Front Options IMPORTANT NOTE: The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. OVERALL DIMENSIONS A Wolf stainless steel and integrated drawer fronts allow for many design options, but the warming drawer itself will be the same for all applications.
Installation Considerations 7 wolfappliance.com/specs Installation Options STANDARD, RECESSED OR FLUSH INSET INSTALLATION The warming drawer with E series drawer front can be installed in a standard, recessed or flush inset application. For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame. A recessed installation requires the cabinetry be recessed by 3/16" (5) so the collar is flush with the cabinet face frame but the drawer front will sit proud.
Warming Drawer Specifications 8 Standard Installation L SERIES, E SERIES OR INTEGRATED DRAWER FRONT ANTI-TIP BLOCK 91/8" (232) OPENING HEIGHT DIMENSION WILL VARY* 10 3/8" 28 5/8" (727) OPENING WIDTH (264) E PLATFORM 24" (610) min 36" (914) 23 1/2" FLOOR TO COUNTERTOP (597) TYPICAL CABINET DEPTH SIDE VIEW FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. NOTE: Location of electrical supply within opening may require additional cabinet depth.
Warming Drawer Specifications 9 wolfappliance.
Warming Drawer Specifications 10 Standard Tower Installation INSTALLATION WITH MICROWAVE AND BUILT-IN OVEN 1" (25) min L SERIES 11/2" (38) min MICROWAVE OPENING E SERIES E 24" (610) min OPENING DEPTH 27 3/16" (691) 28 1/2" (724) OVEN OPENING WIDTH 4" (102) 5" PLATFORM* (127) E E 9 1/8" (232) 3/4" (19) min 28 5/8" (727) WARMING DRAWER OPENING WIDTH SIDE VIEW FRONT VIEW *Platform must support 250 lbs (113 kg).
Warming Drawer Specifications 11 wolfappliance.
Warming Drawer Specifications 12 Flush Inset Tower Installation INSTALLATION WITH CONVECTION MICROWAVE AND E SERIES OVEN TOP VIEW 1" (25) 24 3/4" (629) min FLUSH INSET DEPTH SIDE CLEATS 30 3/8" (772) min FLUSH INSET WIDTH 1/2" (13) TOP CLEAT 18 7/8" (479) 20 1/8" OPENING HEIGHT (511) FLUSH INSET HEIGHT 271/2" (699) CONVECTION MICROWAVE OPENING WIDTH 1 5/8" (41) PLATFORM E 27 3/16" (691) OPENING HEIGHT 28 1/8" (714) min FLUSH INSET HEIGHT 28 1/2" (724) E SERIES OVEN OPENING WIDTH 1" (25) 4" PLA
Warming Drawer Specifications 13 wolfappliance.
Warming Drawer Installation 14 Anti-Tip Block Install the Warming Drawer INSTALL ANTI-TIP BLOCKING Unpack the warming drawer on a flat surface. Remove all packaging materials from inside the warming drawer. Do not discard the package containing the two wood screws needed for installation. Install an anti-tip block against the rear cabinet wall. When the warming drawer is installed below a built-in oven, you may use a 7/8" (22) thick platform to allow the warming drawer trim and the oven trim to meet.
Service Information 15 wolfappliance.com/specs Troubleshooting Service Information IMPORTANT NOTE: If the warming drawer does not operate properly, follow these troubleshooting steps: If service is necessary, maintain the quality built into your warming drawer by contacting Wolf factory certified service. • Verify that electrical power is being supplied to the warming drawer. • Check electrical connections to ensure that the installation has been completed correctly.
WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 816978 REV-A 1/ 2011 WOLFAPPLIANCE.COM 800.222.