design guide

subzero.com/specs
|
51
Plumbing Requirements
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must not
interfere with installation of the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply
1
/4" OD copper, braided stainless
steel, or PEX tubing
Pressure 35–120 psi (2.4–8.3 bar)
Excess Line for Connection 36" (914)
WATER SUPPLY LOCATION
A
18" Model 3" (76)
24" Model 5
1
/2" (140)
30" Model 6" (152)
36" Model 9" (229)
INTEGRATED REFRIGERATION
Electrical Requirements
Locate the electrical supply within the shaded area shown in
the illustration and chart below. A separate circuit servicing
only this appliance is required.
IMPORTANT NOTE: For outdoor model ID-24RO, a ground
fault circuit interrupter (GFCI) is required to reduce the risk
of electrical shock. A GFCI is not recommended for use with
indoor models and may cause interruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
ELECTRICAL SUPPLY LOCATION
A
18" Model 6" (152)
24" Model 9
1
/2" (241)
27" Model 11" (279)
30" Model 12
1
/2" (318)
36" Model 15
1
/2" (394)
A
1
/4" (6)
1
/4" (6)
4
1
/4"
(108)
4
1
/2"
(114)
FLOOR
LEFT SIDE
OF OPENING
Electrical supply location
3" (76)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
A
Water supply location
BUILT-IN PRO 48 INTEGRATED WINE UNDERCOUNTER