Built-In Refrigeration Installation Guide
BUILT-IN REFRIGERATION Contents Important Note 3 Built-In Refrigeration 4 Opening Dimensions To ensure this product is installed and operated as safely and efficiently as possible, take note of the following types of highlighted information throughout this guide: 8 Dual Installation 8 Electrical important. 9 Plumbing 9 Preparation CAUTION indicates a situation where minor injury or product damage may occur if instructions are not followed.
BUILT-IN REFRIGERATION Product Information Tools and Materials Important product information including the model and serial number of the unit are listed on the product rating plate. The rating plate is located at the top frame of the unit, inside the door. Refer to the illustration below. t Screwdrivers—standard and Phillips. t Power drill. t Drill bits (masonry bits required for concrete installation).
SITE PREPARATION Opening Dimensions STANDARD INSTALLATION TOP VIEW 24" (610) OPENING DEPTH 24" (610) OPENING DEPTH 83 3/4" A (2127) OPENING HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW OPENING WIDTH A BI-36R, BI-36RG, BI-36F 35 1/2" BI-30U, BI-30UG 29 1/2" (746) BI-36U, BI-36UG, BI-36UFD 35 1/2" (902) BI-36S 35 1/2" (902) (902) BI-42S, BI-42SID, BI-42SD 41 1/2" (1054) BI-48S, BI-48SID, BI-48SD 47 1/2" (1206) 4 | Sub-Zero Customer Care 800.222.
SITE PREPARATION Opening Dimensions FLUSH INSET INSTALLATION TOP VIEW 26 3/16" 24" (610) DEPTH (665) FLUSH TO CLEAT INSET DEPTH 11/4" (32) UNIT WITH 3/4" (19) PANEL CLEAT 26 3/16" 24" (610) TOP VIEW (665) OPENING FLUSH DEPTH INSET TO CLEAT DEPTH CLEAT 3" (76) typical DETAIL A 2 3/16" (56) 2 3/16" 1/4" (6) (56) 11/4" CLEAT (32) 24" (610) DEPTH TO CLEAT Detail A 2 3/16" (56) 26 3/16" (665) FLUSH INSET DEPTH 3" typical (76) CLEAT 83 3/4" 4" (102) (2127) HEIGHT TO CLEAT A 11/4" WID
SITE PREPARATION Opening Dimensions DUAL STANDARD INSTALLATION TOP VIEW 24" (610) OPENING DEPTH 24" (610) OPENING DEPTH 83 3/4" A (2127) OPENING HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW OPENING WIDTH A Two 30" (762) Models 59 3/4" 30" (762) and 36" (914) Models 65 3/4" (1670) Two 36" (914) Models 71 3/4" (1822) 6 | Sub-Zero Customer Care 800.222.7820 (1518) A dual installation kit will be required for this installation.
SITE PREPARATION Opening Dimensions DUAL FLUSH INSET INSTALLATION TOP VIEW 26 3/16" 24" (610) DEPTH (665) FLUSH TO CLEAT INSET DEPTH 11/4" (32) TWO UNITS WITH 3/4" (19) PANEL CLEAT 26 3/16" 24" (610) TOP VIEW (665) OPENING FLUSH DEPTH INSET TO CLEAT DEPTH CLEAT 3" (76) typical DETAIL A 2 3/16" (56) 2 3/16" 1/ 4" (6) (56) 11/4" CLEAT (32) 24" (610) DEPTH TO CLEAT Detail A 2 3/16" (56) 26 3/16" (665) FLUSH INSET DEPTH 3" typical (76) CLEAT 83 3/4" 4" (102) (2127) HEIGHT TO CLEAT A
SITE PREPARATION Dual Installation Electrical If two units are installed side by side, a dual installation kit may be required. Installations without a custom filler strip require a dual installation kit. If a dual installation kit is not specified, a 2" (51) filler strip is recommended between units. Dual installations without a filler strip can only be accomplished using two units with opposite hinges. Refer to the illustrations below. Installation must comply with all applicable electrical codes.
SITE PREPARATION Plumbing Preparation Installation must comply with all applicable plumbing codes. Uncrate the unit and inspect for damage. Remove the wood base and discard shipping bolts and brackets. Remove and recycle packing materials. Do not discard the kickplate, antitip brackets and hardware. The water supply line should be located within the shaded area shown in the illustrations below. The water supply line should be connected to the house supply with an easily accessible shut-off valve.
SITE PREPARATION Anti-Tip Bracket WARNING To prevent the unit from tipping forward and provide a stable installation, the unit must be secured in place with the anti-tip brackets. The two anti-tip brackets must be installed exactly 24" (610) from the front of the opening to the back of the brackets and a minimum of 4" (102) from the sides of the opening. This depth will increase to 26 3/16" (665) for a flush inset installation based on 3/4" (19) thick panels.
SITE PREPARATION Anti-Tip Bracket CONCRETE WEDGE ANCHOR INSTALLATION: 3/8" CAUTION 1 Drill a (10) diameter hole any depth exceeding the minimum embedment. Clean the hole or drill additional depth to accommodate drill fines. Always wear safety glasses and use other necessary protective devices or apparel when installing or working with anchors. 2 Assemble the washer and nut flush with the end of anchor to protect threads.
INSTALLATION Placement CAUTION Before moving the unit into position, secure door(s) closed and protect any finished flooring. Use an appliance dolly to move the unit near the opening. If the unit has been on its back or side, it must stand upright for a minimum of 24 hours before connecting power. Plug the power cord into the grounded outlet and roll the unit into position. Verify the anti-tip brackets are properly engaged.
PANEL INSTALLATION Custom Panels For overlay and flush inset applications, custom door and grille panels must be installed. Panel size is critical for a proper fit. To verify panel requirements and dimensions, refer to the Sub-Zero design guide at subzero.com/specs. IMPORTANT NOTE: Flush inset applications require a minimum 1/2" (13) reveal on all sides. Finish all sides of custom panels. They may be visible when the door is open or through the window of glass door models.
PANEL INSTALLATION Custom Panels DOOR PANELS To install custom door panels, remove the handle side trim molding. Insert a screwdriver tip into the top corner slot on the handle side and pop out the trim. For the drawer, insert a screwdriver tip into the slot on either side of the trim running along the top of the drawer and pop out the trim. Remove the screws and frame. Refer to the illustrations below. The door has a 1/4" (6) frame for the custom panel to slide into.
PANEL INSTALLATION Custom Panels GRILLE PANEL SIDE PANEL Remove the bottom grille frame by extracting the lower two corner screws from each side of the grille assembly. Refer to the illustration below. When installing a custom side panel, an accessory kit is required and is available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com.
INSTALLATION Alignment LEVELING DOOR ADJUSTMENT Once the unit is in position, turn the front leveling legs clockwise to adjust the height. The rear height adjustment can be made from the front of the roller base. Using a 3/8" socket, turn the 3/8" hex bolt clockwise to raise the unit or counterclockwise to lower. Use the lowest torque setting when using a power drill. Do not turn the rear leveling legs by hand. Refer to the illustration below.
INSTALLATION Completion GRILLE INSTALLATION ANCHORING Install the grille assembly and check for proper fit. The grille is designed to rest on the upper door hinge(s) to minimize the reveal between the top of the door and bottom of the grille. To eliminate interference, the grille height can be adjusted. Loosen the four grille adjustment screws (two on each side) and adjust the grille height as needed. Refer to the illustration below.
INSTALLATION Completion Reinstall the drain pan and verify it is in the proper position. WATER FILTER BYPASS Install the kickplate using screws to attach it to brackets on the inside of each roller base. Refer to the illustration below. The kickplate must be removable for service. The floor cannot interfere with removal. Refer to the label mounted on the kickplate support for height clearance.
INSTALLATION Completion 90° DOOR STOP The doors of all models open to 110°. A 90° door stop is provided with the unit (located behind the grille). Additional 90° door stop kits are available through an authorized Sub-Zero dealer. WARNING Follow all city and state laws when storing, recycling or discarding unused refrigerators and freezers.
SUB-ZERO, INC. P.O. BOX 44848 MADISON, WI 53744 7021793 REV-C 9 / 2012 SUBZERO.COM 800.222.