Design Guide

subzero.com | 91
Electrical Requirements
Locate the electrical supply within the shaded area shown
in the illustration below. A separate circuit servicing only
this appliance is required.
IMPORTANT NOTE: For indoor models, a ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause
interruption of operation.
For the outdoor model, a ground fault circuit interrupter
(GFCI) is required to reduce the risk of electrical shock.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
1
/4" (6)
4"
(102)
3"
(76)
9"
(229)
FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location
Plumbing Requirements
MODEL DEU2450CI
For ease of installation, recess the water shut o into the
wall or place it in an adjacent cabinet. Locate the water
supply line within the shaded area shown in the illustra-
tion below. Connect the water supply line to the house
supply with an easily accessible shut-o valve. Do not use
self-piercing valves.
An in-line filter is required when water conditions have a
high sediment content.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing
codes.
PLUMBING REQUIREMENTS
Water Supply Line ⁄" OD copper, braided
stainless steel, or PEX tubing
Water Pressure 35–120 psi (2.4–8.3 bar)
Excess Water Line for Connection 5' (1.5 m)
4"
(102)
3"
(76)
9"
(229)
LEFT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
Water supply location
Designer Undercounter Refrigeration