ELECTRICAL LOCATION—INTEGRATED
A
18" Model 6" (152)
24" Model 9
1
/2" (241)
30" Model 12
1
/2" (318)
WINE STORAGE
Electrical
The electrical supply must be located within the shaded
area shown in the illustration for your specic model. For
integrated (IW) models, also refer to the chart. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
If the unit will be connected to a home security system,
allow 36"
(914) of excess wiring for proper connection.
IMPORTANT NOTE: For integrated (IW) models, the electrical
outlet must be positioned with the grounding prong to the
right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type