Design Guide

subzero.com | 25
Dual Installation
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom filler strip
require a dual installation kit. If a dual installation kit is not
specified, a 2"
(51) filler strip is recommended between the
units. A custom filler strip is required when installing two
French door or side-by-side models. Dual installations
without a filler strip can only be accomplished using two
84"
(2134) units with opposite hinges. Refer to the illustra-
tions below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the
find a showroom section of our website, subzero.com.
For questions regarding the installation, call Sub-Zero
Customer Care at 800-222-7820.
WITHOUT FILLER STRIP
FILLER STRIP
Opposite hinges
Same side hinges
For dual standard installations, panel dimensions are the
same as for single installations. Refer to the charts on
pages 20–23. Panel dimensions and osets for dual flush
inset installations are listed on the following pages.