Design Guide

92
|
Sub-Zero Customer Care 800.222.7820
UNDERCOUNTER REFRIGERATION
Electrical
The electrical supply should be located within the shaded
area shown in the illustrations below. A separate circuit,
servicing only this appliance is required.
IMPORTANT NOTE: For outdoor models UC-24RO and
UC-15I(P)O, a ground fault circuit interrupter (GFCI) is
required to reduce the risk of electrical shock. A GFCI is not
recommended for use with other undercounter models and
may cause interruption of operation.
Installation must comply with all applicable electrical codes.
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
E
E
LOCATE
ELECTRICAL
SUPPLY IN
ADJACENT
CABINET
24" Models.
Ice Machine.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
UNDERCOUNTER WINE INTEGRATED PRO 48 BUILT-IN