D O W N D R A F T V E N T I L AT I O N I NSTALLATION I NSTRUCTIONS
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed.
W O L F D OW N D R A F T V E N T I L A T I O N S Y S T E M S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Installer: Please read the entire Installation Instructions prior to installation. Save these instructions for the local inspector’s reference, then leave them with the homeowner.
W O L F D OW N D R A F T V E N T I L A T I O N S Y S T E M S Model DD30 Model DD36 Model DD45 D OW N D R A F T V E N T I L A T I O N OV E R A L L D I M E N S I O N S IMPORTANT NOTE: Wolf downdraft ventilation systems are recommended for use with Wolf framed electric, gas, induction and multi-function cooktops. They cannot be used with unframed electric cooktops and are not recommended for use with the electric grill, steamer and fryer modules.
I N S TA L L AT I O N I N S T R U C T I O N S B L OW E R O P T I O N S CONTROL K I T S Wolf downdraft Models DD30I, DD36I and DD45I include a 500 CFM internal blower. Models DD30R, DD36R and DD45R are shipped without a blower assembly and can be used with the remote blowers listed below. Remote blowers are available as sales accessories. IMPORTANT NOTE: The downdraft must be used with a Wolf-approved control module and top cover.
W O L F D OW N D R A F T V E N T I L A T I O N S Y S T E M S I N S TA L L AT I O N S P E C I F I C A T I O N S Wolf downdraft Model DD30 will fit most 30" (762) wide cabinets, Model DD36 will fit most 36" (914) wide cabinets and Model DD45 will fit most 45 1/2" (1156) wide cabinets. It is recommended that oversized cabinets be used for easier installation. Cabinet backs may need to be removed. Wolf downdraft ventilation systems can be mounted in an island, peninsula or standard wall location.
I N S TA L L AT I O N I N S T R U C T I O N S For installation of a downdraft system with a cooktop, refer to the cooktop installation instructions for the dimensions of the cooktop, countertop cut-out and cabinet requirements. The depth of the cooktop may vary and will affect the location of the downdraft in the countertop.
W O L F D OW N D R A F T V E N T I L A T I O N S Y S T E M S ELECTRICAL R E Q U I R E M E N T S I M P O R TA N T N OT E You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Wolf downdraft ventilation systems require a separate, grounded 120 V, 60 Hz power supply. The service should have its own 15 amp circuit breaker, and a grounded 3-prong receptacle should be located within the reach of the 2 1/2' (.8 m) power cord.
I N S TA L L AT I O N I N S T R U C T I O N S B L OW E R C O N S I D E R AT I O N S A D J U S TA B L E D I S C H A R G E The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. A straight, short duct run with a limited number of elbows and transitions will allow the downdraft to perform most efficiently.
W O L F D OW N D R A F T V E N T I L A T I O N S Y S T E M S D U C T I N G C O N S I D E R AT I O N S IMPORTANT NOTE: Always consult a qualified HVAC Engineer for specific ducting applications. IMPORTANT NOTE: Wolf ventilation downdraft systems must be vented to the outside. Use only metal ductwork. Wolf downdraft ventilation systems are designed for use with 3 1/4" (83) x 10" (254) ductwork for Models DD30I, DD36I and DD45I, and 3 1/4" (83) x 14" (356) ductwork for Models DD30R, DD36R and DD45R.
I N S TA L L AT I O N I N S T R U C T I O N S A D J U S T I N G B L OW E R D I S C H A R G E Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles. The blower is shipped with the discharge facing down. D OW N TO L E F T O R R I G H T D I S C H A R G E D OW N D I S C H A R G E L E F T TO R I G H T Follow these steps if it is necessary to rotate the blower to the left or right discharge location.
W O L F D OW N D R A F T V E N T I L A T I O N S Y S T E M S D O W N D R A F T I N S TA L L AT I O N C U T T H E C O U N T E RTO P Lay out and cut the cooktop cut-out far enough forward so the downdraft will fit behind it. Set the cooktop in place and slide it as far forward as possible. Center and square the cooktop with edges of countertop. Place the plastic template included with the downdraft against the back flange of the cooktop and centered. Trace around the template to mark the downdraft opening.
I N S TA L L AT I O N I N S T R U C T I O N S D O W N D R A F T I N S TA L L AT I O N I N S TA L L D U C T W O R K INTERNAL BLOWER WIRING Models DD30I, DD36I and DD45I To reduce the risk of fire, use only metal ductwork. IMPORTANT NOTE: Before cutting the hole in the cabinet for ductwork, check for interference with floor joists, wall studs, electrical wiring or plumbing. Cut the hole in the cabinet as well as holes in wall or floor as necessary for the ductwork.
W O L F D OW N D R A F T V E N T I L A T I O N S Y S T E M S D O W N D R A F T I N S TA L L AT I O N R E M OT E B L OW E R W I R I N G I N S TA L L T H E T O P C O V E R Models DD30R, DD36R and DD45R Models DD30 and DD36 only Mount a standard 120 V AC electrical box, with 3-pronged grounded receptacle, inside the cabinet or adjacent cabinet. Make sure it is located within the reach of the downdraft’s 2 1/2' (.8 m) power cord.
I N S TA L L AT I O N I N S T R U C T I O N S TROUBLES H O OT I N G IMPORTANT NOTE: If the downdraft ventilation system does not operate properly, follow these troubleshooting steps: Verify that power is being supplied to the downdraft. Check electrical connections to ensure that the installation has been completed correctly. Refer to the Troubleshooting Guide in the Wolf Downdraft Ventilation Use & Care Information. If the downdraft still does not work, contact a Wolf authorized service center.